background image

11

Specifications

Product Manual - APPS 160

Inlet Check 

Valve

Inlet Strainer

Inlet 

Connection

Control Box

On / Off 

Switch

Fill Valve 

Indicator Light

Vent Valve 

Indicator Light

Summary of Contents for APPS-160

Page 1: ...Part Number 11929931 Rev B 2014 Chart Inc Designed and Built by Chart Inc 407 7th Street NW New Prague MN 56071 USA 800 400 4683 Product Manual APPS 160...

Page 2: ......

Page 3: ...al 1 Terms 1 Acronyms Abbreviations 2 Safety 3 General 3 Nitrogen and Argon 4 Installation Operation 5 Installation 5 Start Up 5 Operation 5 Adjustments 6 Operating Pressure 6 Liquid Nitrogen Level 6...

Page 4: ...iv Table of Contents Product Manual APPS 160 Revision Log Revision Level Date Description B 07 25 2014 Convert to new layout and combine with manual PN 13428250 for 220V...

Page 5: ...e control on liquid use Mini bulk storage for under sized vacuum lines Low cost alternative to two bulk tanks Two operating pressure ranges available Stainless steel plumbing Product Manual The APPS 1...

Page 6: ...onyms abbreviations are used throughout this manual APPS 160 Adjustable Pressure Phase Separator dB Decibel GPM Gallons per minute Hz Hertz MAWP Maximum Allowable Working Pressure OD Outer Dimension P...

Page 7: ...posed to an atmosphere containing only 8 to 12 oxygen In this environment unconsciousness can be immediate with virtually no warning When the oxygen content of air is reduced to about 15 to 16 the fla...

Page 8: ...r sustain life Inhalation of high concentrations of these gases can cause anoxia resulting in dizziness nausea vomiting or unconsciousness and possibly death Individuals should be prohibited from ente...

Page 9: ...properly installed The APPS 160 unit should be purged with warm dry nitrogen gas prior to introducing liquid to ensure that the unit does not have moisture in the inner vessel Turn APPS unit power swi...

Page 10: ...ution To monitor adjustment power must be on and wires will be powered or hot Turn large brass hex nut In or clockwise will decrease set point Out or counterclockwise will increase set point Replace c...

Page 11: ...valve or over tightened valve bolts The bolts should not be tighter than 12 foot pounds and should be evenly torqued If the gasket between the bodies leaks it needs to be replaced Mark the location of...

Page 12: ...8 Product Manual APPS 160...

Page 13: ...ction 1 2 male 45 flare 1 2 male 45 flare 1 2 male 45 flare 1 2 male 45 flare Outlet connection 1 female MVE bayonet 1 female MVE bayonet 1 female MVE bayonet 1 female MVE bayonet Vent connection 1 2...

Page 14: ...Vessel PRV 100 psig 11915572 11915572 11915572 11915572 Vessel SRV 150 psig 11915581 11915581 11915581 11915581 Inlet piping RV 235 psig 1810062 1810062 1810062 1810062 Vent regulator 11756911 211058...

Page 15: ...11 Specifications Product Manual APPS 160 Inlet Check Valve Inlet Strainer Inlet Connection Control Box On Off Switch Fill Valve Indicator Light Vent Valve Indicator Light...

Page 16: ...ions Product Manual APPS 160 Control Box hot black wire connection Control Box neutral white wire connection Control Box ground green wire connection Liquid Level switch connections Liquid Level switc...

Page 17: ...13 Specifications Product Manual APPS 160 Pressure switch connections Pressure switch adjustments Control Box Electrical Schematic...

Page 18: ...14 Product Manual APPS 160...

Reviews: