www.charltonandjenrick.co.uk
25
LT5558 (ISS 7)
FIT STANDARD FIRE TRIM , FRET & FASCIA
Fit the fire with the magnetic strips placed on the vertical side flange of the box. Avoid placing magnets along the
top section of the trim.
For four-sided trim fitting see instructions supplied with trim.
Offer the decorative trim up squarely and centrally and push into position.
To remove the decorative trim, simply pull away from the magnetic strips.
Fit the fire fret by standing on the hearth OR plinth in front of the fire.
ADVISE CUSTOMER THAT:
The glass front of this fire acts as a dress guard, conforming to BS 1945 (1997) and satisfies the heating appliance
regulations (1991) however; a fireguard conforming to BS6539 (1997) must be used to protect young children,
the elderly, or infirm.
The curing effect of heating the coals and other refractory components will cause an initial odour. This is due to
the starch used in the manufacturing process and is non-toxic.
The fret is hand cast in brass and some minor imperfections may be found on the surface.
Any debris should be cleaned from the appliance. A vacuum cleaner can be used but only after all the loose coals
have been removed.
The appliance should be serviced annually by a competent person in accordance with these instructions and the
appliance checked for spillage in accordance with the method detailed in these instructions.
Demonstrate the lighting and extinguishing procedures to the user and the removal and refitting of the brass
trim fret and glass panel for cleaning. Refer to the user section of this booklet.
If ventilation is fitted for any reason it must be checked regularly to ensure freedom from obstructions.
Hand these instructions over to the user.
SECTION ELEVEN Maintenance (maintenance instructions)
GENERAL
Servicing should be carried out annually by a competent person such as a GAS SAFE-registered person in
accordance with the relevant regulations, to ensure the safe and correct operation of the appliance.
Before commencing any service or replacement of parts, turn off the gas supply to the fire. After servicing check
for gas soundness.
When ordering spare parts please quote appliance name and serial number, these can be found on the data
badge, which is located on the left hand side of the appliance behind the trim or fascia.
At least once a years check for debris in the catchment area behind the fire and in the flue way.
If soot has accumulated checks to establish cause rectify and clean flue or chimney accordingly.
PILOT LINTING
Check pilot aeration holes for linting, use a vacuum cleaner nozzle taking care not to damage the pilot head.
Summary of Contents for PARAGON FOCUS 18 HE
Page 27: ...www charltonandjenrick co uk 27 LT5558 ISS 7 ...