www.charltonandjenrick.co.uk
15
LT5558 (ISS 7)
SECTION SIX Appliance Data (installation instructions)
NATURAL GAS
Gas Type:
CATEGORY I 2 H
Gas Pressure:
20 mbar +/- 1.0mbar
Pressure Test Point Location:
Gas inlet elbow
Gas Input:
5.7 kW Gross (Max.)
3.0 kW Gross (Min.)
Injectors:
Mk 365
Oxy pilot:
9044
Gas Connection:
8mm compression: semi-rigid or rigid
Data Badge Location: Located on bottom left hand side of the appliance behind the trim/fascia.
Appliance Dimensions
NOTE: The efficiency of this appliance has been measured as specified in BS7977-1 2009 + A1: 2013 and the result is 73.8%. The gross calorific
value of the fuel has been used for this efficiency calculation. Gastec have certified the test data from which it has been calculated. The
efficiency value may be used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings. Please note: The
restrictor fitted to the appliance is there to achieve the maximum efficiency. This, however, may require removal where a flue is
underperforming.
When unpacking the appliance please check the following items are included:
Fuel Bed:
Coal or Pebble:
Wire Fixing Kit (Including magnets ),Foam sealing strip, Owner’s Manual,
Trim and Fret or Fascia.
250
310
450
430
555
Summary of Contents for PARAGON FOCUS 18 HE
Page 27: ...www charltonandjenrick co uk 27 LT5558 ISS 7 ...