LT-FSDC-H
Page 4 of 11
1
st
Printing
4
Remove and set aside the screws from the
plastic outer gasket.
Remove and set aside the metal compression
plate that seals the express loop plug in the
port.
Disassemble and set aside the plastic outer
gasket and set the components aside.
5
Locate the attachment plate in the FSDC-H
closure.
There are two brackets for securing a strength
member and two slots for attaching a hose
clamp.
6
Obtain a cable and remove the sheath from a
6.5 to 7.0 foot (max. 7.0 ft.) section. Cut the
strength member to a 2.5 to 3.0
” length on
both sides of the unsheathed section.
Discard sheathing and scrap strength member
according to local practice.
Push and feed a 6.5 to 7.0 foot (max. 7.0 ft.)
length of unsheathed cable into the express
loop-through hole.
7
Guide the strength members on each side of
the cable loop under the clamps, using a
Philips screwdriver to tighten the clamps in
place.
Use a 6 mm hose clamp on each cable to
secure in place (clamps included in the
accessory bag).
8
Take the previously removed plastic inner
gasket and connect the pieces around the
sheathed cables. Push this grommet inward
into the express loop port.
Fit the rubber middle gasket around the
cables. Push this gasket inward into the
express loop port.
9
Reassemble the previously removed plastic
outer gasket around the cables.
Put the previously removed metal
compression plate back in place and retrieve
the express port screws. Use the 5 mm (or
3/16”) Allen wrench to secure the express port
sealing components together in the express
loop port.
Compression
Plate