![Chargery BMS24T Series Manual Download Page 4](http://html1.mh-extra.com/html/chargery/bms24t-series/bms24t-series_manual_2591419004.webp)
LiPo & LiFe, LiTo Battery Management System BMS24T V4.0
www.chargery.com
page 4 total 41
Order information
Model
Description
Accessories
BMS24T-100
100A charge and discharge
100A shunt, and standard accessories
BMS24T-300
300A charge and discharge
300A shunt, and standard accessories
BMS24T-600
600A charge and discharge
600A shunt, and standard accessories
All standard accessories are listed on page 30
,
includes:
1.
Battery balance wire, 3pcs
2.
Relay controller wire, 1pcs
3.
Temperature wire, 1pcs
4.
Current sensor wire, 1pcs
5.
Current shunt, 1pcs
6.
USB data cable, 1pcs
7.
Communication wire on COM2, connect main unit
to display module, 1pcs
8.
Communication wire on COM3, connect BMS to
external device, 1pcs
9.
Warning LED, 1pcs
10.
Warning beeper, 1pcs
Optional accessories
1.
12V 100A relay
2.
12V 200A relay
3.
12V 400A relay
4.
12V 600A relay
5.
12V 800A relay
6.
Relay delay time board
Notes:
BMS24T includes Main Unit and Display Module, after powering on the
BMS24T and finishing setting up all of the parameters using the
Display Module. The BMS24T will use those settings even if the
Display Module is disconnected from the Main Unit. This disables the data display, beeper and warning LED
but the BMS will still function properly and can cut off charge / discharge when any set condition requires it.
You can connect an external device to the COM3 port on Main Unit to receive all data. More information on
this is located here:
http://chargery.com/uploadFiles/bms24_additional_protocol%20V1.22.pdf
To modify the
parameters in setup, please reconnect the Display Module, no data can be written to the BMS from an
external application at this time.
The BMS24T can be used with any lithium battery charger, when any cell is over charged, the BMS24T will
open the charge relay to cut off charge, if used with a CHARGERY charger, the charge control is handled by
connecting the CHARGERY charger to the BMS24T on COM1, when any cell reach OVP, the charge current will
decrease automatically to prevent any cell damage. This feature can save charge relay cost and shorten
charge time.