EMERGENCIES:

 If a gas leak cannot be stopped, or a fire occurs due to gas leakage, call the fire department.

Emergencies

Problem

Gas leaking from LP 
cylinder.

Gas leaking between 
LP cylinder and 

connection.

Fire coming through 

control valve connection

Grease fire or 
continuous excessive 
flames above cooking 
surface.

Burner(s) will not  light 
using ignitor.

Continued on next 
page.

Possible Cause

Possible Cause

•Mechanical failure due to rusting or 

mishandling.

•Improper installation, connection not 

tight, failure of rubber seal.

• Fire in burner tube section of burner due 

to blockage.

• Too much grease buildup in trough.

GAS ISSUES:

• Burner not engaged with regulator control

• Obstruction in burner.

• No gas flow.

• Regulator Control Valve and LP cylinder 

valve not fully connected.

ELECTRICAL ISSUES:

•Electrode cracked or broken; “sparks at 

crack.”

•Electrode and burner are wet

•Wire and/or electrode covered with 

cooking residue.

•Wires are loose or disconnected.

•Wires are shorting (sparking) between 

ignitor and electrode.

Prevention/Solution

Prevention/Solution

•Replace LP cylinder.

• Remove regulator control valve from cylinder and 

visually inspect  for damage. See LP Cylinder Leak Test 

and Connecting Regulator control valve to the LP Cylinder.

•Turn off control knob. Leave lid open to 

allow flames to die down. After fire is out and grill is cold, remove 
burner and inspect for spider nests or rust. See Natural Hazard 
and Cleaning the Burner Assembly pages.

• Turn off control knob and LP cylinder valve. Leave lid open to 

allow flames to die down. After cooling, clean food particles and 
excess grease from inside firebox area, grease cup, and other 
surfaces.

• Make sure regulator control valve is  positioned inside of burner tube.

• Ensure burner tube is not obstructed with spider webs or other 

matter. See cleaning section of Use and Care.

• Make sure LP cylinder is not empty.

• Remove LP cylinder. Clean threads on LP cylinder and regulator 

control valve.

• Replace electrode(s).

Wipe dry with a cloth.

•Clean wire and/or electrode with rubbing alcohol and clean swab.

•Reconnect wires or replace electrode/wire assembly.

•Replace ignitor wire/electrode assembly.

Troubleshooting

REV00

Page 9

regulator control valve

at burner/regulator

valve.

• Regulator Control Valve knob does NOT

stay down in ON positions.

• Replace regulator control valve.

• Regulator Control Valve knob does NOT

pop up in the OFF position.

• Replace regulator control valve.

Summary of Contents for Grill 2 Go 11401587

Page 1: ...nsumer CONSUMER Keep this manual for future reference WARNING Failure to follow all manufacturer s instructions could result in serious personal injury and or property damage CAUTION Some parts may co...

Page 2: ...e liquid 4 If a fire should occur keep away from the appliance and immediately call your fire department Do not attempt to extinguish an oil or grease fire with water Failure to follow these instructi...

Page 3: ...dard for Recreational Vehicles ANSI A119 2 NFPA 1192 and Recreational Vehicle Code CSA Z240 RV Series as applicable All electrical accessories such as rotisserie must be electrically grounded in accor...

Page 4: ...erials that burn i e gasoline propane or any other flammable liquid or gas Do not block holes in bottom or back of grill Check burner flames regularly Never use regulator from this grill with any othe...

Page 5: ...tch lighting stick light match 2 Insert lit match through gap between trough and grill bottom next to burner Turn regulator control knob to HIGH setting 3 If ignition does NOT occur in 5 seconds turn...

Page 6: ...lame from burner should be blue Fire coming from around or behind control knob Follow the instructions Clean burner often Use a 12 pipecleaner to clean out the burner tube You may also force a stream...

Page 7: ...commend food to be at least 40 F before cooking in your appliance Whole poultry should reach 165 F Juices should run clear and flesh should not be pink Beef veal and lamb steaks roasts and pork chops...

Page 8: ...sponsible for any consequential or incidental damages arising from the breach of either this limited warranty or any applicable implied warranty or for failure or damage resulting from acts of God imp...

Page 9: ...cylinder and visually inspect for damage See LP Cylinder Leak Test and Connecting Regulator control valve to the LP Cylinder Turn off control knob Leave lid open to allow flames to die down After fire...

Page 10: ...food buildup in trough Burner and or burner tubes are blocked Prevention Solution Replace ignitor Inspect wire insulation and proper connection Replace ignitor wires electrode assembly if insulation i...

Page 11: ...REGTEMP REV02 Warranty Registration Department P O Box 1240 Columbus Ga 31902 1240 Page 11...