5. Hold regulator, insert nipple (B) into LP tank valve. Hand tighten coupling nut, holding
regulator in a straight line (C) with LP tank valve so as not to cross thread the
connection.
6. Turn the coupling nut clockwise to tighten to a full solid stop. The regulator will seal on
the back-check feature in the LP tank valve, resulting in some resistance. An additional
one-half to three quarters turn is required to complete connection. Tighten by hand only
— do not use tools.
NOTE: If you cannot complete connection, disconnect regulator and repeat steps 5 and 6.
If you are still unable to complete the connection,
do not use this regulator!
WARNING
Hold coupling nut and regulator as shown
for proper connection to LP tank valve.
Nipple must be centered
into the LP tank valve.
B
C
Straight
10
• Do not insert any tool or foreign object into the valve outlet or safety relief valve. You
may damage the valve and cause a leak. Leaking propane may result in explosion, fire,
severe personal injury, or death.
• Never attempt to attach this appliance to the self-contained LP gas system of a camper
or trailer or motor home.