Limited Warranty

This warranty is extended to the original purchaser of an evaporative cooler installed and used under nor-
mal conditions.  It does not cover damages incurred through accident, neglect, or abuse by the owner.  We 
do not authorize any person or representative to assume for us any other or different liability in connection 
with this product.

Terms And Conditions Of The Warranty

For One Year from date of purchase, we will replace any original component provided by Champion 
Cooler which fails due to any defect in material or factory workmanship only.

Exclusions From The Warranty

We are not responsible for replacement of evaporative media.  These are disposable components and 
should be replaced periodically.  We are not responsible for any incidental or consequential damage result-
ing from any malfunction.

We are not responsible for any damage received from the use of water softeners, chemicals, de-scale mate-
rial or plastic wrap.

We are not responsible for the cost of service calls to diagnose the cause of trouble, or labor charge to 
repair and/or replace parts.

How To Obtain Service Under This Warranty

Contact the Dealer where you purchased the evaporative cooler.  If for any reason you are not satisfi ed 
with the response from the dealer, contact the Customer Service Department:  Champion Cooler, 5800 
Murray Street, Little Rock, Arkansas 72209.  1-800-643-8341.  [email protected]

This limited warranty applies to the original purchaser only.

Register your product online at www.championcooler.com/eac/onlineregistration-eac.htm

Maintenance

 

WARNING:  Before doing any maintenance be sure unit is unplugged.

Drain Unit

To drain the unit, remove the media frame and remove the rubber drain stopper from the bottom of the unit 
by pulling it out of the drain hole.  The unit should be drained periodically to keep the water fresh.  We 
recommend draining the unit once a week.  Drain the water from the unit when it will not be used for an 
extended period. 

Note:  To remove the media frame, fi rst remove the two screws located at the top of the frame (see 
fi g. 4).  Tilt the frame back while pressing on the bottom of the frame where it says “Push” until it 
snaps out, then lift out.  The water distribution hose can be removed from the media frame to allow 
complete separation of media frame from unit.  Do not operate unit with media frame removed.

Clean/Replace Evaporative Media

The evaporative media should be cleaned twice a season or when 
needed.  To clean the media, rinse with clean water.  Light scrub-
bing might be necessary.  Be careful not to damage media.  After 
2 years, or when it becomes clogged, the media will need to be 
replaced.  To remove the media, fi rst remove the keeper disks from 
the keeper stems (see fi g. 4).  Remove the keeper stems from the 
media and remove the media.

When replacing the evaporative media, install it so that the steeper 
fl ute angle of the media is sloping down towards the media frame 
(see fi g. 4).  Push the keeper stems through the media from the 
back of the media frame and press the keeper disks onto the stems 
to secure the media in place.

3

Keeper 

Disk

Keeper 

Stem

Fig. 4

45°

15°

Screw

Summary of Contents for UltraCOOL CP70

Page 1: ...nce WARNING To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device 110489 5 5 09 Evaporative Cooling Evaporative cooling is an economical way to cool Air is cooled while being drawn across wet evapora tive media The movement of this fresh cooled air over the skin is what makes it feel cool It is important when using an evaporative cooler in a...

Page 2: ... minutes after the last button on the control is pushed Pump Cooler Operation To operate this unit as an evaporative cooler the unit must be filled with water and the pump powered on Press the Pump button to turn on the pump The water drop indicator on the display will flash while the pump is on To operate the unit as a fan only press Pump to turn off the pump Note The pump will not run if the wat...

Page 3: ...ser only Register your product online at www championcooler com eac onlineregistration eac htm Maintenance WARNING Before doing any maintenance be sure unit is unplugged Drain Unit To drain the unit remove the media frame and remove the rubber drain stopper from the bottom of the unit by pulling it out of the drain hole The unit should be drained periodically to keep the water fresh We recommend d...

Page 4: ...d Replacement Parts No Description CP70 1 Evaporative Media 110132 3 2 Evaporative Media Frame Assembly 110874 1 3 Water Tray 110874 3 4 Water Distributor Nozzle 110874 4 5 Keepers Set of 4 110871 6 Pump 110439 1 7 Drain Plug 110698 8 Float Assembly 110873 9 Swivel Casters Non Locking 110822 6 10 Swivel Casters Locking 110822 7 11 Pedestal 110874 2 12 Water Distributor Tubing 110734 1 13 M4 x 12mm...

Page 5: ...con el aparato ADVERTENCIA Para reducir el riesgo de incendio o toques eléctricos no use este ventilador con ningún dispositivo de estado sólido para controlar la velocidad del ventilador Modelo CP70 Enfriamiento Por Evaporación El enfriamiento por evaporación es una manera económica de enfriarse El aire se enfría mientras se traza a través de medio evaporativo mojado El movimiento de este aire en...

Page 6: ...n Funcionamiento Del Enfriador Bomba Para funcionar esta unidad como enfriador evaporativo necesita llenar la unidad con agua y presionar el bo tón Pump para arrancar la bomba El indicador de gotas de agua en la pantalla en la sección de la bomba parpadeará cuando la bomba está prendido Para funcionar la unidad como ventilador solamente presione Pump para apagar la bomba Nota La bomba no funcionar...

Page 7: ...en línea a www championcooler com eac onlineregistration eac htm Conservación ADVERTENCIA Siempre desconecte el enfriador antes de procurar cualquier tipo de servicio Drenar La Unidad Para drenar la unidad quite la armazón del medio evaporativo y quite el tapón de goma del desagüe situado en la parte inferior de la unidad Necesita drenar la unidad periódicamente para mantener el agua dulce Re come...

Page 8: ...onectó Piezas De Repuesto n Descripción CP70 1 Medio Evaporativo 110132 3 2 Montaje De Armazón Del Medio Evaporativo 110874 1 3 Canal De Agua 110874 3 4 Boquilla De Distribuidor De Agua 110874 4 5 Equipo De 4 Sujetadores 110871 6 Bomba 110439 1 7 Tapón De Goma 110698 8 Flotador y Indicador De Agua 110873 9 Rueda Giratoria Sin Frena 110822 6 10 Rueda Giratoria Con Frena 110822 7 11 Pedestal 110874 ...