Separator Filter and Refrigerated Air Dryer (cont’d)
As previously noted, the Separator Filter is located between the Air End and the Refrigerated Dryer. It contains a
1 micron Separator Element which protects the Dryer Unit by removing liquids and solid particles 1 micron and
larger.
To replace a dirty Filter Element:
•
Shut the Compressor Unit off.
•
Bleed any compressed air from the system to ensure there is no pressure at the Filter.
•
Unscrew the Bowl from the assembly and remove the filter element
•
Clean any debris from the inside of the Bowl
•
Remove the O-ring from the inside of the Canister Head
•
Install the new O-ring making sure it is properly seated
•
Place the new 1 micron Separator Filter Element into the Bowl (the filter is self-centring).
•
Screw the Canister with the Element inside it to the Canister Head until the indicators line up.
•
Gauge will return to
green
when Filter is once again under pressure.
Typical Separator Filter
Dual Indicating Gauge (DF001)
Arrow pointing to Green = Filter Element is Clean
Arrow pointing to Red = Filter Element is Dirty
The label shown above is included with a
replacement Filter Element and should be
affixed to the outside of the Bowl for future
reference.
Filter Element Replacement
Arrow Indicates
Direction of Air Flow
Alignment
Indicators:
triangles on
canister and
head will align &
prevent further
tightening when
canister is
secured to the
head
Float Drain (DF003)
Bowl which Contains Filter Element
DF18A
Summary of Contents for D5