Changing from Straight-through to Corner Operation (cont’d)
Refer to Fig. 2 and perform the steps below.
1.
Remove the front rack guide (A). Discard the square spacers.
2.
Move front rack guide (A) to the left side of the rack tracks. (See Fig. 2b) Use existing
hardware.
3.
Unbolt the track (B) and rack support rod (C).
4.
Remove and save the two remaining fasteners from rear track.
5.
Bolt (B) and (C) as shown in Fig. 2b.
Electrical Connections
WARNING:
Electrical and grounding connections must comply with the National Electrical Code
and/or Local Electrical Codes.
WARNING:
When working on the dishwasher, disconnect the electric service and place a tag at the
disconnect switch to indicate work is being done on that circuit.
1.
A qualified electrician must compare the electrical power supply with the machine
electrical specifications stamped on the MACHINE ELECTRICAL CONNECTION
PLATE located inside the top mounted control cabinet before connecting to the incoming
service at a fused disconnect switch.
2.
Motor rotation was set at the factory. Check the rotation of the motor shaft (CW when
viewed from rear of motor). For three phase machines, reversing the motor direction is
done in the control cabinet by reversing the wires L1 and L2 on the disconnect side of the
main electrical connection block. For single phase machines, motor rotation is changed at
the motor connection plate on the rear of the single phase motor.
10
INSTALLATION
!
!
Figure 2a
Straight-Through Configuration
Figure 2b
Corner Configuration
A
B C
A
B
C
Figure 2
Changing the Track Assembly
Summary of Contents for D-H1M3
Page 31: ...29 REPLACEMENT PARTS REPLACEMENT PARTS ...
Page 62: ...1 2 3 60 REPLACEMENT PARTS Figure 37 D HB D H1 D LF Dishracks and PRV ...
Page 64: ...62 REPLACEMENT PARTS THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 65: ...63 ELECTRICAL SCHEMATICS ELECTRICAL SCHEMATICS ...
Page 68: ......
Page 69: ......