Chemical Connections (cont’d)
Rinse Aid/Sanitizer (cont’d)
Model D-LF
Refer to Fig. 9
1.
A rinse aid injection point is provided via a 1/4" NPT plug located in the final rinse piping.
The plug is located in a cross fitting on the outlet side of the vacuum breaker. The vacuum
breaker is located behind the control cabinet at the top of the machine.
2.
Use a liquid rinse aid.
3.
A sanitizer injection point is provided via a 1/8" NPT plug located in the final rinse piping.
The plug is located in a cross fitting on the outlet side of the vacuum breaker. The vacuum
breaker is located behind the control cabinet at the top of the machine.
4.
Use a sodium hypochlorite (Chlorine) based sanitizer at a minimum concentration of
50PPM in the final rinse.
Use chlorine test papers to verify and monitor the 50PPM chlorine level.
WARNING:
Never premix rinse aid with the sanitizing agent. Mixing may cause hazardous gases to form.
CAUTION:
Some metal, including silver, aluminum, and pewter are attacked by sodium hypochlorite
(chlorine sanitizer). Avoid cleaning these metals in a D-LF dishwasher.
15
INSTALLATION
Figure 9
D-LF
Rinse Aid/Sanitizer Injection Points
1/4" NPT plug
Rinse aid injection point
1/8" NPT plug
Sanitizer injection point
!
!