Troubleshooting
26
Rev 73552i-20100621 E
Troubleshooting
Problem
Cause
Solution
Generator will not start
No fuel
Add fuel
Faulty spark plug
Replace spark plug
Unit loaded during start up
Remove load from unit
Generator will not start;
Generator starts but runs roughly
Low oil level
Fill crankcase to the proper level
Place generator on a flat, level surface
Choke in the wrong position.
Adjust choke.
Spark plug wire loose
Attach wire to spark plug
Generator shuts down during
operation
Out of fuel
Fill fuel tank
Low oil level
Fill crankcase to the proper level.
Place generator on a flat, level surface
Generator cannot supply enough
power or overheating
Generator is overloaded
Review load and adjust. See “Power
Management”
Insufficient ventilation
Check for air restriction. Move to a
well ventilated area
No AC output
Cable not properly connected
Check all connections
Connected device is defective
Replace defective device
Circuit breaker is open
Unplug electrical loads. Turn off
generator. Restart.
Faulty inverter assembly
Replace
Loose wiring
Inspect and tighten wiring
connections
Other
Contact the help line.
Engine governor defective
Contact the help line
Repeated circuit breaker tripping
Faulty cords or device
Check for damaged, bare or frayed
wires. Replace defective device
Summary of Contents for 73552i
Page 2: ......
Page 4: ......
Page 22: ...Specifications 18 Rev 73552i 20100621 E Parts Diagram ...
Page 25: ...Specifications Rev 73552i 20100621 E 21 Engine Parts Diagram ...
Page 26: ...Specifications 22 Rev 73552i 20100621 E ...
Page 29: ...Specifications Rev 73552i 20100621 E 25 Wiring Diagram ...