Operation
10
Rev 73552i-20100621 E
Operation
Generator Location
Please consult your local authority. In some
areas, generators must be registered with
the local utility.
Generators used at construction sites may be
subject to additional rules and regulations.
This generator must have at least five feet of
clearance from combustible material. Leave
at least three feet of clearance on all sides of
the generator to allow for adequate cooling,
maintenance and servicing.
Place the generator in a well-ventilated area.
DO NOT place the generator near vents or
intakes where exhaust fumes could be drawn
into occupied or confined spaces. Carefully
consider wind and air currents when
positioning generator.
Starting the Engine
1.
Make certain the generator is on a flat,
level surface.
2.
Disconnect all electrical loads from the
generator. Never start or stop the
generator with electrical devices plugged
in or turned on.
3.
Turn the fuel cap vent lever to the “On”
position.
4.
Turn the fuel valve to the “On” position.
5.
Turn the engine switch to the “On”
position.
6.
Pull the choke lever out when starting
the generator.
7.
Pull the starter cord slowly until
resistance is felt and then pull rapidly
8.
As engine warms up, push the choke
lever in.
NOTE
If the engine starts but does not run, make
certain that the generator is on a flat, level
surface. The engine is equipped with a low oil
sensor that will prevent the engine from running
when the oil level falls below a critical threshold.
Summary of Contents for 73552i
Page 2: ......
Page 4: ......
Page 22: ...Specifications 18 Rev 73552i 20100621 E Parts Diagram ...
Page 25: ...Specifications Rev 73552i 20100621 E 21 Engine Parts Diagram ...
Page 26: ...Specifications 22 Rev 73552i 20100621 E ...
Page 29: ...Specifications Rev 73552i 20100621 E 25 Wiring Diagram ...