Storage
The generator should be started at least once every 14
days and allowed to run for at least 20 minutes . For
longer term storage, please follow these guidelines .
Generator Storage
1 . Allow the engine to cool completely before storage .
2 . Clean the generator according to the instructions in
the Maintenance section .
3 . Remove the maintenance cover . Drain all fuel
completely from the fuel line and carburetor to
prevent varnish build up .
4 . Remove the spark plug cap, then pull the recoil grip 3
times to drain the gasoline from the carburetor jets .
5 . Change the engine oil .
6 . Remove the spark plug and pour about a tablespoon
of oil into the cylinder . Crank the engine slowly to
distribute the oil and lubricate the cylinder .
7 . Reattach the spark plug .
MAINTENANCE ANd STORAGE
Generator Maintenance
Make certain that the generator is kept clean and stored
properly . Only operate the unit on a flat, level surface in
a clean, dry operating environment . DO NOT expose the
unit to extreme conditions, excessive dust, dirt, moisture
or corrosive vapors .
Use a damp cloth to clean exterior surfaces of the generator .
Use a soft bristle brush to remove dirt and oil .
Use an air compressor (25 PSI) to clear dirt and debris
from the generator .
Inspect all air vents and cooling slots to ensure that they
are clean and unobstructed .
Generator Maintenance Cont’d.
Adjustments
The air-fuel mixture is not adjustable . Tampering with
the governor can damage your generator and your
electrical devices and will void your warranty . CPE
recommends that you contact our service line at
1-877-338-0999 for all other service and/or adjustment
needs .
Maintenance Schedule
Follow the service intervals indicated in the following
maintenance schedule .
Service your generator more frequently when operating
in adverse conditions .
Contact our help line at
1-877-338-0999 to locate the
nearest Champion Power Equipment certified service
dealer for your generator or engine maintenance needs .
*To be performed by knowledgeable, experienced owners or
Champion Power Equipment certified dealers .
Every 8 hours or daily
Check oil level
Clean around air intake and muffler
First 5 Hours
Change oil
Every 50 hours or every season
Clean air filter
Change oil if operating under heavy load or in hot
environments
Every 100 hours or every season
Change oil
Clean/Adjust spark plug
Check/Adjust valve clearance *
Clean spark arrester
Clean fuel tank and filter *
Every 3 years
Replace fuel line
DO NOT use a garden hose to clean the generator .
Water can enter the generator through the cooling
slots and damage the generator windings .
CAUTION