Generator Location
Please consult your local authority . In some areas,
generators must be registered with the local utility .
Generators used at construction sites may be subject to
additional rules and regulations .
This generator must have at least five feet of clearance
from combustible material . Leave at least three feet
of clearance on all sides of the generator to allow for
adequate cooling, maintenance and servicing .
Place the generator in a well-ventilated area . DO NOT
place the generator near vents or intakes where exhaust
fumes could be drawn into occupied or confined
spaces . Carefully consider wind and air currents when
positioning generator .
Starting the Engine
1 . Make certain the generator is on a flat, level surface .
2 . Disconnect all electrical loads from the generator .
Never start or stop the generator with electrical
devices plugged in or turned on .
3 . Turn the fuel cap vent lever to the “On” position .
4 . Turn the fuel valve to the “On” position .
5 . Slide choke lever right to the “Choke” position .
6 . Turn the engine switch to the “On” position .