REV 46555-20110708
14
46555
ENGLISH
Maintenance Schedule
Follow the service intervals indicated in the following
maintenance schedule .
Service your generator more frequently when operating
in adverse conditions .
Contact our help line at
1 (877) 338-0999
to locate the
nearest Champion Power Equipment certified service
dealer for your generator or engine maintenance needs .
*To be performed by knowledgeable, experienced owners or
Champion Power Equipment certified dealers .
Every 8 hours or daily
Check oil level
Clean around air intake and muffler
First 5 Hours
Change oil
Every 50 hours or every season
Clean air filter
Change oil if operating under heavy load or in hot
environments
Every 100 hours or every season
Change oil
Clean/Adjust spark plug
Check/Adjust valve clearance *
Clean spark arrester
Clean fuel tank and filter *
Every 3 years
Replace fuel line
Adjustments
The air-fuel mixture is not adjustable . Tampering with
the governor can damage your generator and your
electrical devices and will void your warranty . CPE
recommends that you contact our service line at
1 (877) 338-0999
for all other service and/or
adjustment needs .
Use a damp cloth to clean exterior surfaces of the engine .
Use a soft bristle brush to remove dirt and oil .
Use an air compressor (25 PSI) to clear dirt and debris
from the engine .
Cleaning
DO NOT spray engine with water .
CAUTION
Water can contaminate the fuel system .
MAINTENANCE ANd STORAGE
Generator Maintenance
Make certain that the generator is kept clean and stored
properly . Only operate the unit on a flat, level surface in
a clean, dry operating environment . DO NOT expose the
unit to extreme conditions, excessive dust, dirt, moisture
or corrosive vapors .
Use a damp cloth to clean exterior surfaces of the generator .
Use a soft bristle brush to remove dirt and oil .
Use an air compressor (25 PSI) to clear dirt and debris
from the generator .
Inspect all air vents and cooling slots to ensure that they
are clean and unobstructed .
DO NOT use a garden hose to clean the generator .
Water can enter the generator through the cooling
slots and damage the generator windings .
CAUTION
Air filter
1 . Remove the snap-on cover holding the air filter to
the assembly .
2 . Remove the foam element .
3 . Wash in liquid detergent and water . Squeeze
thoroughly dry in a clean cloth .
4 . Saturate in clean engine oil .
5 . Squeeze in a clean, absorbent cloth to remove all
excess oil .
6 . Place the filter in the assembly .
7 . Reattach the air filter cover and snap in place .