15
REV 46555-20110708
ENGLISH
46555
Storage
The generator should be started at least once every 14
days and allowed to run for at least 20 minutes . For
longer term storage, please follow these guidelines .
Generator Storage
1 . Allow the engine to cool completely before storage .
2 . Clean the generator according to the instructions in
the Maintenance section .
3 . Turn off the fuel supply at the Fuel Valve .
4 . Drain all fuel completely from the fuel line and
carburetor to prevent gum from forming .
5 . Add a fuel stabilizer into the fuel tank .
6 . Change the oil .
7 . Remove the spark plug and pour about ½ ounce
of oil into the cylinder . Crank the engine slowly to
distribute the oil and lubricate the cylinder .
8 . Reattach the spark plug .
9 . Store the unit in a clean, dry place out of direct
sunlight .
MAINTENANCE ANd STORAGE
disconnect the Battery
1 . Remove the protective cover from the black/negative
battery lead .
2 . Disconnect the black/negative lead from the black/
negative terminal on the battery and store the cap
screw (M6x10) and lock washer (M6) .
3 . Repeat steps 1-2 for the red/positive battery lead .
4 . Store the battery in a cool, dry place .
Charge the Battery
Proper battery maintenance and storage should
be followed . A 12V automatic battery charger with
automatic trickle charging capability should be used to
charge the battery . Maximum charging rate should not
exceed 2 amps . Follow the instructions included with
the battery charger . The battery should be fully charged
at least once per month .
Generator exhaust contains odorless and colorless
carbon monoxide gas .
To avoid accidental or unintended ignition of your
electric start generator during periods of storage,
the following precautions should be followed:
– When
storing the generator for short periods of
time make sure that the Ignition Switch and the
Fuel Valve are switched to the
OFF position .
– When
storing the generator for extended periods
of time make sure that the Ignition Switch
and the Fuel Valve are switched to the the
OFF position and the battery leads have been
disconnected from the battery .
dANGER
A Float Charger will maintain the battery condition
over long storage periods .
NOTE