Installation
CONDENSATE LINES MUST BE GRAVITY DRAIN WITH NO BACK PRESSURE.
A CONDENSATE LIFT PUMP MUST BE INSTALLED IF THE CONDENSATE
IS ABOVE THE FINISHED FLOOR.
STANDARD REQUIRED STEAM SUPPLY PRESSURE IS 10-30 PSI.
STEAM CONNECTION IS ALWAYS LOCATED AT THE RIGHT SIDE OF THE MACHINE.
CHECK THE STEAM SUPPLY PRESSURE REQUIREMENTS
PRIOR TO CONNECTING THE STEAM SUPPLY LINES.
WATER HARDNESS OF 3 GRAINS/US GAL - 0.83 IMP GAL -5.3mg/L or LESS.
MINIMUM 1-1/4" NPT STEAM LINE.
TANK HEAT: lbs./hr. required at 15 PSI = 75
STEAM BOOSTER: lbs./hr. required 40
°
F Rise AT 15 PSI = 60
STEAM BOOSTER: lbs./hr. required 70
°
F AT 15 PSI = 85
CAUTION:
The dishwasher steam connections must comply with all local plumbing,
health and safety codes. Damage caused by improper installation is not covered by
the limited warranty
STEAM
Steam Connections
Steam Heating