200978 - 4500W DUAL FUEL OPEN FRAME INVERTER
OPERATION
22
4. Pull the recoil cord slowly until resistance is felt and then pull
rapidly.
5. Do not over-choke. As soon as engine starts, turn the EZ
Start dial to the gasoline “RUN” position.
NOTICE
For gasoline restarts with hot engine in hot ambient
temperature >86°F (30°C):
Rotate the EZ Start dial to
the “CHOKE” position for only one pull of the recoil cord. If
generator does not start after first pull, rotate the dial to the
“RUN” position for the next three pulls. Too much choke leads
to spark plug fouling and engine flooding. This will cause the
engine not to start.
NOTICE
For gasoline starting in standard ambient temperature
>59°F (15°C):
Keep EZ Start dial in “CHOKE” position for three
pulls of the recoil cord. If generator does not start after three
pulls, rotate the EZ Start dial to the “RUN” position for the next
three pulls. Too much choke leads to spark plug fouling and
engine flooding. This will cause the engine not to start.
NOTICE
If the engine starts but does not run make certain that the
generator is on a flat, level surface. The engine is equipped
with a low oil sensor that will prevent the engine from running
when the oil level falls below a critical threshold.
Starting the Engine: Propane (LPG)
1. Make certain the generator is on a flat, level surface.
2. Disconnect all electrical loads from the generator. Never start
or stop the generator with electrical devices plugged in or
turned on.
3. Fully open the fuel valve on the LPG cylinder.
4. Turn the EZ Start dial to the propane “CHOKE” position.
5. Slowly pull the starter cord 3-5 times to prime the engine.
6. Turn the EZ Start dial to the propane “RUN” position.