background image

100593 - 3200 PORTAbLE POwER STATiON

iMPORTANT SAfETY iNSTRUCTiONS

6

 

wARNiNG

 

Do not use a Power Station or appliance that is damaged 
or modified. Damaged or modified internal batteries may 
exhibit unpredictable behavior resulting in fire, explosion or 
risk of injury.

 

Do not remove cover. No user serviceable parts inside.

 

Do not tamper or disassemble the Power Station to attempt 
service or replace the battery. Incorrect reassembly may 
result in a risk of fire, electric shock or personal injury. 

 

For service information please contact our Champion 
Technical Support Team at 1-877-338-0999. Please have 
your serial number and model number available when 
service, repair or replacement is required.

 

Never place fingers or hands inside the product.

 

wARNiNG

 

To reduce the risk of injury or damage, avoid contact with 
any hot surface.

 

Do not use the Power Station near sources of high heat or 
fire. Exposure to fire or temperature above 266°F (130°C) 
may cause explosion.

 

Do not discharge the Power Station battery in 
temperatures below 5°F (-15°C) or above 104°F (40°C).

 

Do not allow fluids to flow into the Power Station. Corrosive 
or conductive fluids, such as seawater, certain industrial 
chemicals, and bleach or bleach containing products, etc., 
can cause a short circuit.

 

Follow all charging instructions and do not charge the 
Power Station outside the temperature range specified in 
the instructions. Charging improperly or at temperatures 
outside the specified range may damage the battery and 
increase the risk of fire.

When charging the Power Station:

 

Always charge the Power Station’s internal battery in a  
well-ventilated area.

 

Do not use the AC charging cable outdoors.

 

Do not expose AC charging cable to oil, oil vapor, grease, 
gasoline, gasoline vapors or other caustic substances that may 
damage the AC charging cable.

 

Do not charge the internal battery below 32°F (0°C) or above 
113°F (45°C).

 

Do not charge Power Station in rain, snow, damp or wet 
locations.

 

Do not overcharge the Power Station internal battery.

 

Always connect to properly grounded outlets.

 

Never use Power Station or charger in the presence of 
explosive atmospheres (gaseous fumes, dust or flammable 
materials).

 

Never leave the Power Station unattended while charging. 
If the internal battery smokes, or gives off an odor during 
charging, terminate charging immediately.

 

During charging, if the Power Station battery becomes hot 
to the touch, stop charging. Allow battery to cool before 
resuming.

 

Always unplug charger when not in use.

 

To reduce the risk of electric shock, always unplug charger 
before cleaning or maintenance. Do not allow water to flow 
into plug. Use a Ground Fault Circuit Interrupter (GFCI) to 
reduce shock hazards.

Grounding Information:

 

The Power Station must be grounded. This product is equipped 
with a cord having a grounding conductor and grounding 
plug. The plug must be plugged into an outlet grounded in 
accordance with all local codes and ordinances.

 

Improper connection of the Power Station grounding conductor 
can result in a risk of electric shock. Check with a qualified 
electrician if you are in doubt as to whether the product is 
properly grounded. 

 

Do not modify the plug provided with the Power Station – if it 
will not fit into the outlet, have a proper outlet installed by a 
qualified electrician.

When storing the Power Station:

 

This Power Station is intended to be stored indoors and shall 
not be stored or left outdoors when not in use.

 

Do not stack any items on top of the Power Station during 
storage. 

 

Store your Power Station and charger in a cool, dry place 
between -4°F (-20°C) and 104°F (40°C). 

 

Do not store Power Station where temperatures may exceed 
120°F (50°C) such as in direct sunlight, in a vehicle or metal 
buildings especially during the summer.

 

Do not store the Power Station near sources of high heat or 
fire.

 

Do not store the Power Station when discharged to 20% or 
less state of charge (SOC).

 

Lithium batteries must be charged regularly to perform well. 
The Power Station must be fully charged by you at least once 
every 6 months (180 days).

Summary of Contents for 100593

Page 1: ...mpionpowerequipment com READ AND SAVE THIS MANUAL This manual contains important safety precautions which should be read and understood before operating the product Failure to do so could result in se...

Page 2: ...nnect DC Solar Charge Harness 20 Recommended Solar Panels 21 Using APP Port 21 Operation 22 Using the Power Station 22 Standby Mode 22 LED Light 22 Connecting Electrical Loads 23 Resetting the Output...

Page 3: ...ort has been made to ensure the accuracy and completeness of the information in this manual at the time of publication and we reserve the right to change alter and or improve the product and this docu...

Page 4: ...ratings on the Power Station and accessory products you intend to use CAUTION In outdoor conditions this device is intended for temporary outdoor use only Reasonable care should always be exercised wh...

Page 5: ...wer tools Connect only to properly grounded outlets To reduce risk of damage to the electric plug and cord pull the plug rather than the cord when disconnecting the Power Station Never use the cord fo...

Page 6: ...rain snow damp or wet locations Do not overcharge the Power Station internal battery Always connect to properly grounded outlets Never use Power Station or charger in the presence of explosive atmosp...

Page 7: ...es and counties it may be illegal to dispose of these batteries in standard household waste To dispose the battery safely apply tape over any exposed connectors to prevent accidental shorting of the p...

Page 8: ...ALE V CC 46 8 CHEMISTRY CHIMIE CURRENT CAPACITY Ah CAPACIT ACTUELLE Ah 70 PACK CAPACITY Wh BLOC ALIMENTATION Wh 3276 Charging Temperature F C Temp rature de Charge F C 32 113 0 45 5 104 15 40 Discharg...

Page 9: ...electrician to determine grounding requirements before operation Electric Shock Failure to use in dry conditions and to observe safe practices can result in electric shock Shield eyes Explosive gases...

Page 10: ...roduct uses lithium ion Li ion batteries Local state or federal laws prohibit disposal of Li ion batteries in ordinary trash In the United States and Canada a large network of over 30 000 battery drop...

Page 11: ...for 3 seconds to power ON OFF Press for 1 second to power AC outlets ON OFF Circuit Breaker Reset Push Parallel Connection s AC Output DC Output 12V Direct Current Ground Terminal Neutral Floating Ne...

Page 12: ...ower output when the AC running watts are too high and it can no longer maintain a pure sine wave 5 THD The letters THD will appear in red See THD Shield Total Harmonic Distortion section The Power St...

Page 13: ...arge 120V AC 60Hz 4 5A MAX Used to charge the Power Station from a regular wall outlet Uses included cord 7 DC Fast Charge MPPT Solar 10V 28V DC 25A MAX APP Anderson Power Pole DC Used to charge the P...

Page 14: ...ole May be used to supply electrical power for operation of 12 Volt DC 20 Amp electrical loads B z 12V DC 10A Regulated Automotive May be used to supply electrical power for operation of 12 Volt DC 10...

Page 15: ...ady blue Steady red if overloaded or fault has occurred in 120V AC inverter or outlets see Resetting the Output section 12 THD Shield Disabled Steady blue when THD Shield disabled and THD below 5 Flas...

Page 16: ...to charge to full 0 watts out battery is at 10 H 1 2 W Charging Watts Example 384 Watts charging in 0 watts out battery is at 10 1 2 W W Discharging Hours Example 2 0 Hours to empty 0 watts in batter...

Page 17: ...HD steady red AC output shut off due to THD above 5 1 2 W W THD Shield Disabled THD 5 Example THD Shield disabled icon will be steady blue when THD is below 5 AC output will not shut off until battery...

Page 18: ...experiencing a fault See figure to the right 12V DC USB Port Fault Example Fault in 12V DC port location 1 APP and USB port location 3 USB PD Check devices cables or lower load Press overload reset bu...

Page 19: ...pt RSS standard s Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accept any interference including interference that may cause und...

Page 20: ...itive equipment Surge suppressors come in single or multi outlet styles They re designed to protect against virtually all short duration voltage fluctuations Charging From Wall NOTICE The Power Statio...

Page 21: ...Solar Panel 200 Watt 12 Volt 200 MC4 Bluetti SP120 120 MC4 Bluetti SP200 200 MC4 ECOFLOW EFSOLAR 160W 160 MC4 Any solar panel rated between 10 28V with MC4 or APP connectors can be used The Power Stat...

Page 22: ...in a pure sine wave 5 THD The letters THD will appear in red See THD Shield Total Harmonic Distortion section 4 To turn THD Shield off press THD Shield button 5x within three seconds 5 Plug in desired...

Page 23: ...DC outlets 1 Unplug all devices 2 For AC output errors only Check to see if Power Station s circuit breaker is tripped If tripped push in to reset 3 Press the reset button 4 If overload is due to high...

Page 24: ...r Management Use the following formula to convert voltage and amperage to watts Volts Amps Watts To prolong the life of your Power Station and attached devices follow these steps to add electrical loa...

Page 25: ...ly with water No user serviceable parts for maintenance required Water can enter the Power Station through the cooling slots and damage the Power Station electronics 1 Use a damp cloth to clean exteri...

Page 26: ...5 3 cm Width 10 8 in 27 5 cm Height 15 7 in 39 8 cm Battery Specifications Chemistry Lithium ion NMC Pack Rated Output Voltage 46 8 Pack Max Output Voltage 55 Pack Capacity 3276 Wh Single Cell Equival...

Page 27: ...perature warning light Turn the unit off place it in the shade or a cooler area and let it cool down Check that the unit is not overloaded Unit is too cold Check display for flashing red Low Temperatu...

Page 28: ...you reach 440W of charging power Unit is nearing 100 battery level and is slowing down to a safer charging rate The charging power and rate is reduced as the battery level gets closer to 100 to safely...

Page 29: ...ot apply to parts and or labor if the product is deemed to have been misused neglected involved in an accident abused loaded beyond the product s limits modified installed improperly or connected inco...

Reviews: