background image

100593 - 3200 PORTAbLE POwER STATiON

iMPORTANT SAfETY iNSTRUCTiONS

4

iMPORTANT SAfETY iNSTRUCTiONS

 

wARNiNG

Cancer and Reproductive Harm – www.P65Warnings.ca.gov

 

wARNiNG

Read all safety warnings and all instructions. Failure to follow 
the warnings and instruction may result in electric shock, fire 
and cause serious injury. Save all warnings and instruction.

 

DANGER

Power Station generates powerful voltage.

Keep your Power Station in a dry, well-ventilated area when in 
use.

Do not operate the Power Station with a damaged cord, plug, 
or a damaged output cable. Use only Champion electrical cords 
for proper application.

Do not allow children or unqualified persons to operate or 
service the Power Station.

Do not operate Power Station in wet conditions. To avoid short 
circuits or electric shock do not allow unit to get wet. In the 
event the unit does get wet, let the unit dry completely before 
using.

Always use a ground fault circuit interrupter (GFCI) in damp 
areas and areas containing conductive material such as metal 
decking.

Do not allow fluids to flow into Power Station. Corrosive or 
conductive fluids, such as seawater, industrial chemicals, 
bleach or bleach containing products can cause a short circuit.

This equipment has internal arcing or sparking parts which 
should not be exposed to flammable vapors or liquids.

 

wARNiNG

To avoid fire or electrical shock hazard, observe all ratings on 
the Power Station and accessory products you intend to use.

 

CAUTiON

In outdoor conditions, this device is intended for temporary 
outdoor use only. Reasonable care should always be exercised 
when using this device outdoors in damp conditions, but 
should never be used in wet conditions.

 

wARNiNG

Do not use Power Station for medical life support uses.

In case of emergency, call 911 immediately.

NEVER use this product to power life support devices or life 
support appliances.

Inform your electricity provider immediately if you or anyone 
in your household depends on electrical medical equipment to 
live.

Inform your electrical provider immediately if a loss of power 
would cause you or anyone in your household to experience a 
medical emergency.

 

wARNiNG

Power Station produces heat. Skin burns can occur on contact.

Do not touch hot surfaces.

Allow equipment to cool before touching.

 

wARNiNG

Exceeding the Power Station’s running capacity can damage 
the Power Station and/or electrical devices connected to it.

DO NOT overload the Power Station.

DO NOT tamper or modify the Power Station in any way.

 

wARNiNG

Improper treatment or use of the Power Station can damage it, 
shorten its life or void the warranty.

Use the Power Station only for intended uses.

DO NOT expose Power Station to moisture, dust, or dirt.

DO NOT allow any material to block the cooling slots.

If connected devices overheat, turn them off and disconnect 
them from the Power Station.

DO NOT use the Power Station if:

 

Electrical output is lost

 

Equipment sparks, smokes or emits flames

 

Equipment vibrates excessively

Summary of Contents for 100593

Page 1: ...mpionpowerequipment com READ AND SAVE THIS MANUAL This manual contains important safety precautions which should be read and understood before operating the product Failure to do so could result in se...

Page 2: ...nnect DC Solar Charge Harness 20 Recommended Solar Panels 21 Using APP Port 21 Operation 22 Using the Power Station 22 Standby Mode 22 LED Light 22 Connecting Electrical Loads 23 Resetting the Output...

Page 3: ...ort has been made to ensure the accuracy and completeness of the information in this manual at the time of publication and we reserve the right to change alter and or improve the product and this docu...

Page 4: ...ratings on the Power Station and accessory products you intend to use CAUTION In outdoor conditions this device is intended for temporary outdoor use only Reasonable care should always be exercised wh...

Page 5: ...wer tools Connect only to properly grounded outlets To reduce risk of damage to the electric plug and cord pull the plug rather than the cord when disconnecting the Power Station Never use the cord fo...

Page 6: ...rain snow damp or wet locations Do not overcharge the Power Station internal battery Always connect to properly grounded outlets Never use Power Station or charger in the presence of explosive atmosp...

Page 7: ...es and counties it may be illegal to dispose of these batteries in standard household waste To dispose the battery safely apply tape over any exposed connectors to prevent accidental shorting of the p...

Page 8: ...ALE V CC 46 8 CHEMISTRY CHIMIE CURRENT CAPACITY Ah CAPACIT ACTUELLE Ah 70 PACK CAPACITY Wh BLOC ALIMENTATION Wh 3276 Charging Temperature F C Temp rature de Charge F C 32 113 0 45 5 104 15 40 Discharg...

Page 9: ...electrician to determine grounding requirements before operation Electric Shock Failure to use in dry conditions and to observe safe practices can result in electric shock Shield eyes Explosive gases...

Page 10: ...roduct uses lithium ion Li ion batteries Local state or federal laws prohibit disposal of Li ion batteries in ordinary trash In the United States and Canada a large network of over 30 000 battery drop...

Page 11: ...for 3 seconds to power ON OFF Press for 1 second to power AC outlets ON OFF Circuit Breaker Reset Push Parallel Connection s AC Output DC Output 12V Direct Current Ground Terminal Neutral Floating Ne...

Page 12: ...ower output when the AC running watts are too high and it can no longer maintain a pure sine wave 5 THD The letters THD will appear in red See THD Shield Total Harmonic Distortion section The Power St...

Page 13: ...arge 120V AC 60Hz 4 5A MAX Used to charge the Power Station from a regular wall outlet Uses included cord 7 DC Fast Charge MPPT Solar 10V 28V DC 25A MAX APP Anderson Power Pole DC Used to charge the P...

Page 14: ...ole May be used to supply electrical power for operation of 12 Volt DC 20 Amp electrical loads B z 12V DC 10A Regulated Automotive May be used to supply electrical power for operation of 12 Volt DC 10...

Page 15: ...ady blue Steady red if overloaded or fault has occurred in 120V AC inverter or outlets see Resetting the Output section 12 THD Shield Disabled Steady blue when THD Shield disabled and THD below 5 Flas...

Page 16: ...to charge to full 0 watts out battery is at 10 H 1 2 W Charging Watts Example 384 Watts charging in 0 watts out battery is at 10 1 2 W W Discharging Hours Example 2 0 Hours to empty 0 watts in batter...

Page 17: ...HD steady red AC output shut off due to THD above 5 1 2 W W THD Shield Disabled THD 5 Example THD Shield disabled icon will be steady blue when THD is below 5 AC output will not shut off until battery...

Page 18: ...experiencing a fault See figure to the right 12V DC USB Port Fault Example Fault in 12V DC port location 1 APP and USB port location 3 USB PD Check devices cables or lower load Press overload reset bu...

Page 19: ...pt RSS standard s Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accept any interference including interference that may cause und...

Page 20: ...itive equipment Surge suppressors come in single or multi outlet styles They re designed to protect against virtually all short duration voltage fluctuations Charging From Wall NOTICE The Power Statio...

Page 21: ...Solar Panel 200 Watt 12 Volt 200 MC4 Bluetti SP120 120 MC4 Bluetti SP200 200 MC4 ECOFLOW EFSOLAR 160W 160 MC4 Any solar panel rated between 10 28V with MC4 or APP connectors can be used The Power Stat...

Page 22: ...in a pure sine wave 5 THD The letters THD will appear in red See THD Shield Total Harmonic Distortion section 4 To turn THD Shield off press THD Shield button 5x within three seconds 5 Plug in desired...

Page 23: ...DC outlets 1 Unplug all devices 2 For AC output errors only Check to see if Power Station s circuit breaker is tripped If tripped push in to reset 3 Press the reset button 4 If overload is due to high...

Page 24: ...r Management Use the following formula to convert voltage and amperage to watts Volts Amps Watts To prolong the life of your Power Station and attached devices follow these steps to add electrical loa...

Page 25: ...ly with water No user serviceable parts for maintenance required Water can enter the Power Station through the cooling slots and damage the Power Station electronics 1 Use a damp cloth to clean exteri...

Page 26: ...5 3 cm Width 10 8 in 27 5 cm Height 15 7 in 39 8 cm Battery Specifications Chemistry Lithium ion NMC Pack Rated Output Voltage 46 8 Pack Max Output Voltage 55 Pack Capacity 3276 Wh Single Cell Equival...

Page 27: ...perature warning light Turn the unit off place it in the shade or a cooler area and let it cool down Check that the unit is not overloaded Unit is too cold Check display for flashing red Low Temperatu...

Page 28: ...you reach 440W of charging power Unit is nearing 100 battery level and is slowing down to a safer charging rate The charging power and rate is reduced as the battery level gets closer to 100 to safely...

Page 29: ...ot apply to parts and or labor if the product is deemed to have been misused neglected involved in an accident abused loaded beyond the product s limits modified installed improperly or connected inco...

Reviews: