Starting the Engine

1.  Make certain the generator is on a flat, level surface. 

2.  Disconnect all electrical loads from the generator. Never 

start or stop the generator with electrical devices plugged 
in or turned on.

3.  Turn the fuel cap vent lever to the “ON” position.

4.  Turn the fuel dial clockwise to the full “ON” position.

5.  Pull choke knob out to the “CHOKE” position.

6.  Pull the recoil cord slowly until resistance is felt and then 

pull rapidly.

7.  As engine warms up, push the choke knob in to the “RUN” 

position.

 

NOTICE

Keep choke lever in “CHOKE” position for only 1 pull of the 
recoil cord. After first pull, press the choke knob in to the 
“RUN” position for up to the next 3 pulls of the recoil cord. 
Too much choke leads to spark plug fouling/engine flooding 
due to the lack of incoming air. This will cause the engine 
not to start.

 

NOTICE

For gasoline restarts with hot engine in hot ambient > 
86°F (30°C):

 If generator does not start after the first pull, 

press the choke knob in to the “RUN” position for the next 
3 pulls. Too much choke leads to spark plug fouling/engine 
flooding due to the lack of incoming air. This will cause the 
engine not to start.

 

NOTICE

For gas starting in cold ambient < 59°F (15°C): 

The 

choke must be in 100% of the “CHOKE” position for manual 
start procedures. Do not over-choke. As soon as engine 
starts, push the choke knob in the “RUN” position.

Summary of Contents for 92001i-EU

Page 1: ...ontains important safety precautions which should be read and understood before operating the product Failure to do so could result in serious injury This manual should remain with the product Specifi...

Page 2: ...ry effort has been made to ensure the accuracy and completeness of the information in this manual at the time of publication and we reserve the right to change alter and or improve the product and thi...

Page 3: ...rester maintain a minimum distance of 5 ft 1 5 m from dry vegetation to prevent fires DANGER Operate equipment with guards in place Rotating parts can entangle hands feet hair clothing and or accessor...

Page 4: ...ns could result When starting engine pull the recoil cord slowly until resistance is felt and then pull rapidly to avoid kickback DO NOT start or stop the engine with electrical devices plugged in and...

Page 5: ...essure from the gasoline tank Only fill or drain gasoline outdoors in a well ventilated area DO NOT pump gasoline directly into the generator at the gas station Always use an approved fuel container t...

Page 6: ...llow current to backfeed into utility lines creating an electrocution hazard A transfer switch must be used when connecting to a building Fire Hazard Fuel and its vapors are extremely flammable and ex...

Page 7: ...hem and learn their meaning Proper interpretation of these symbols will allow you to more safely operate the product SYMBOL MEANING ON STOP or OFF Choke Pull choke knob to CHOKE position Run Push chok...

Page 8: ...by volume 3 Turn the fuel cap vent lever to the ON position 4 Turn the fuel dial clockwise to the full ON position 5 Pull choke knob to CHOKE position 6 Pull the recoil cord 7 Push the choke knob to...

Page 9: ...ls and features Save this manual for future reference Generator 1 Carrying Handle Used to lift or carry the unit 2 Choke Used to start a cold engine 3 Recoil Starter Used to manually start the engine...

Page 10: ...Fault Push to reset 4 Oil Warning Indicator Light When ON engine will shut down and not run Check oil level 5 Economy Mode Button Enables disables automatic idle control 5a OFF Economy Mode is OFF 5b...

Page 11: ...001i EU 1900W Rated Portable Inverter Generator Controls and Features 11 EN Parts Included Accessories Engine Oil 500ml 16 9 fl oz Oil Funnel 1 Dual Port USB Adapter 5v 2 4A 1 Battery Charging Cables...

Page 12: ...that requires no additional lubrication for the life of the bearing NOTICE The recommended oil type for typical use is 10W 30 automotive oil If running generator in extreme temperatures refer to the f...

Page 13: ...cap until you hear a clicking noise Wipe up any spilled fuel CAUTION Use unleaded gasoline with a minimum octane rating of 85 and an ethanol content of 10 or less by volume DO NOT light cigarettes or...

Page 14: ...least 5 ft 1 5 m of clearance from all combustible material In addition to clearance from all combustible material generators must also have at least 3 ft 91 4 cm of clearance on all sides to allow fo...

Page 15: ...sition for only 1 pull of the recoil cord After first pull press the choke knob in to the RUN position for up to the next 3 pulls of the recoil cord Too much choke leads to spark plug fouling engine f...

Page 16: ...Do Not Overload Generator Capacity Follow these simple steps to calculate the running and starting watts necessary for your purposes 1 Select the electrical devices you plan on running at the same tim...

Page 17: ...ucts When using the 12V DC outlet turn the Economy mode switch to the OFF position Be sure all electric devices including the lines and plug connections are in good condition before connection to the...

Page 18: ...altitude for the application of the high altitude carburetor main jet is listed in the following table In order to select the correct high altitude main jet it is necessary to identify the carburetor...

Page 19: ...n the cover screws and remove the maintenance cover 3 Remove oil fill cap dipstick 4 Tilt the generator on its side and allow the oil to drain completely 5 Add oil according to Add Engine Oil in Assem...

Page 20: ...r screen 5 Carefully remove the carbon deposits from the spark arrestor screen with a wire brush 6 Replace the spark arrestor if it is damaged 7 Position the spark arrestor on the muffler and attach b...

Page 21: ...p and clog the carburetor if it isn t used or drained within 2 4 weeks If using the generator within 2 weeks follow the steps according to Stopping the Engine section 1 If not using the generator for...

Page 22: ...use fuel to vaporize resulting in a possible explosion Do not drive on a rough road for an extended period with the washer on board If you must transport the washer on a rough road drain the fuel from...

Page 23: ...hart Capacity 500ml 16 9 fl oz 20 0 20 40 60 Ambient temperature Temperatura ambiente Temp rature ambiante Recommended Oil Type Tipo de aceite recomendado Type d huile recommand 80 100 120 28 9 F C 17...

Page 24: ...odic parts and service to perform well This warranty does not cover repair when normal use has exhausted the life of a part or the equipment as a whole Installation Use and Maintenance This warranty w...

Page 25: ...92001i EU 1900W Rated Portable Inverter Generator 25 EN Parts Diagram...

Page 26: ...olt M5 x 12 1 31 1ZC7DFB06 Engine 79cc 1 32 100033099 0008 Big Flange Bolt M6 x 18 2 33 100131884 Tube Sheath Silicon Resin 1 34 100131883 0001 Fuel Tube L 275mm 1 Part Number Description Qty 35 10009...

Page 27: ...sing Assembly Bottom Black 1 70 100072711 Housing Bottom Black 1 71 100072994 0001 Step Nut M6 6 72 100072710 0001 Rubber Damper 1 73 100011452 0010 Nut M6 4 74 100072712 Foot Bottom Housing 4 75 1000...

Page 28: ...92001i EU 1900W Rated Portable Inverter Generator 28 Engine Parts Diagram...

Page 29: ...ket Cylinder Head 1 33 100010549 Dowel Pin 8 x 12 4 34 100075061 Push Rod 2 35 100075059 Valve Exhaust 1 Part Number Description Qty 36 100159354 Valve Intake 1 37 100075036 Lifter Valve 2 38 10007504...

Page 30: ...Part Number Description Qty 72 100011571 0002 Big Flange Bolt M6 x 14 3 73 100131964 Fuel Bowl Mounting Bolt 1 74 100131960 Fuel Bowl O Ring 1 75 100163552 Main Jet Standard 1 100163549 Main Jet Altit...

Page 31: ...92001i EU 1900W Rated Portable Inverter Generator 31 EN Wiring Diagram...

Page 32: ...he state in which it was placed on the market and excludes components which are added and or operations carried out subsequently by the final user Designation Function Gasoline generating set 1 Type 9...

Page 33: ...e Winch Solutions LTD Address Unit 17 18 Bradley Trading Estate Bradley lane Standish Greater Manchester WN6 0XQ UK 7 Date Place Authorized Signature APRIL 21ST 2020 HANGZHOU LI JIE 8 Title of Signato...

Page 34: ...l 44 0 1942 715 407 technical bpeholdings co uk Germany BPE Solutions Deutschland GmbH Altrottstra e 31 D 69190 Walldorf Germany Tel 49 6227 655996 3 support bpeholdings de Sweden BPE Nordic AB Valn s...

Reviews: