background image

92001i-EU 1900W RATED PORTAbLE INvERTER GENERATOR

IMPORTANT SAFETY INSTRUCTIONS

5

EN

Fuel Safety

 

DANGER

GASOLINE AND GASOLINE VAPORS ARE HIGHLY 
FLAMMABLE AND EXPLOSIVE.

Fire or explosion can cause severe burns or death.

Gasoline and gasoline vapors:

 

Gasoline is highly flammable and explosive.

 

Gasoline can cause a fire or explosion if ignited.

 

Gasoline is a liquid fuel but it’s vapors can ignite.

 

Gasoline is a skin irritant and needs to be cleaned up 
immediately if spilled on skin or clothes.

 

Gasoline has a distinctive odor, this will help detect potential 
leaks quickly.

 

Gasoline expands or contracts with ambient temperatures. 
Never fill the gasoline tank to full capacity, as gasoline 
needs room to expand when temperatures rise.

 

In the case of any petroleum gasoline fire, flames should 
never be extinguished unless the fuel supply valve can be 
turned OFF. By not doing so, if a fire is extinguished and the 
supply of fuel is not turned OFF, an explosion hazard could 
be created.

When adding or removing gasoline:

DO NOT light or smoke cigarettes.

Always turn the generator off and let cool for a minimum of two 
minutes before removing the gasoline cap. Afterwards, loosen 
gasoline cap to relieve pressure from the gasoline tank.

Only fill or drain gasoline outdoors in a well-ventilated area.

DO NOT pump gasoline directly into the generator at the gas 
station. Always use an approved fuel container to transfer the 
gasoline to the generator.

DO NOT overfill the gasoline tank.

Always keep gasoline away from sparks, open flames, pilot 
lights, heat and other sources of ignition.

When starting the generator:

DO NOT attempt to start a damaged generator. 

Always make certain that the gasoline cap, air filter, spark plug, 
fuel lines and exhaust system are properly secured, connected 
and in place.

Always allow spilled gasoline to evaporate fully before 
attempting to start the engine.

Make certain that the generator is resting firmly on level 
ground.

When operating the generator:

DO NOT move or tip the generator during operation.

DO NOT tip the generator or allow fuel or oil to spill.

When transporting or servicing the generator:

Make certain that the fuel valve is in the OFF position and the 
gasoline tank is empty.

Disconnect the spark plug wire.

When storing the generator:

Store away from sparks, open flames, pilot lights, heat and 
other sources of ignition.

Do not store generator or gasoline near furnaces, water heaters, 
or any other appliances that produce heat or have automatic 
ignitions.

 

WARNING

Never use a gasoline container, gasoline tank, or any other 
fuel item that is broken, cut, torn or damaged.

Summary of Contents for 92001i-EU

Page 1: ...ontains important safety precautions which should be read and understood before operating the product Failure to do so could result in serious injury This manual should remain with the product Specifi...

Page 2: ...ry effort has been made to ensure the accuracy and completeness of the information in this manual at the time of publication and we reserve the right to change alter and or improve the product and thi...

Page 3: ...rester maintain a minimum distance of 5 ft 1 5 m from dry vegetation to prevent fires DANGER Operate equipment with guards in place Rotating parts can entangle hands feet hair clothing and or accessor...

Page 4: ...ns could result When starting engine pull the recoil cord slowly until resistance is felt and then pull rapidly to avoid kickback DO NOT start or stop the engine with electrical devices plugged in and...

Page 5: ...essure from the gasoline tank Only fill or drain gasoline outdoors in a well ventilated area DO NOT pump gasoline directly into the generator at the gas station Always use an approved fuel container t...

Page 6: ...llow current to backfeed into utility lines creating an electrocution hazard A transfer switch must be used when connecting to a building Fire Hazard Fuel and its vapors are extremely flammable and ex...

Page 7: ...hem and learn their meaning Proper interpretation of these symbols will allow you to more safely operate the product SYMBOL MEANING ON STOP or OFF Choke Pull choke knob to CHOKE position Run Push chok...

Page 8: ...by volume 3 Turn the fuel cap vent lever to the ON position 4 Turn the fuel dial clockwise to the full ON position 5 Pull choke knob to CHOKE position 6 Pull the recoil cord 7 Push the choke knob to...

Page 9: ...ls and features Save this manual for future reference Generator 1 Carrying Handle Used to lift or carry the unit 2 Choke Used to start a cold engine 3 Recoil Starter Used to manually start the engine...

Page 10: ...Fault Push to reset 4 Oil Warning Indicator Light When ON engine will shut down and not run Check oil level 5 Economy Mode Button Enables disables automatic idle control 5a OFF Economy Mode is OFF 5b...

Page 11: ...001i EU 1900W Rated Portable Inverter Generator Controls and Features 11 EN Parts Included Accessories Engine Oil 500ml 16 9 fl oz Oil Funnel 1 Dual Port USB Adapter 5v 2 4A 1 Battery Charging Cables...

Page 12: ...that requires no additional lubrication for the life of the bearing NOTICE The recommended oil type for typical use is 10W 30 automotive oil If running generator in extreme temperatures refer to the f...

Page 13: ...cap until you hear a clicking noise Wipe up any spilled fuel CAUTION Use unleaded gasoline with a minimum octane rating of 85 and an ethanol content of 10 or less by volume DO NOT light cigarettes or...

Page 14: ...least 5 ft 1 5 m of clearance from all combustible material In addition to clearance from all combustible material generators must also have at least 3 ft 91 4 cm of clearance on all sides to allow fo...

Page 15: ...sition for only 1 pull of the recoil cord After first pull press the choke knob in to the RUN position for up to the next 3 pulls of the recoil cord Too much choke leads to spark plug fouling engine f...

Page 16: ...Do Not Overload Generator Capacity Follow these simple steps to calculate the running and starting watts necessary for your purposes 1 Select the electrical devices you plan on running at the same tim...

Page 17: ...ucts When using the 12V DC outlet turn the Economy mode switch to the OFF position Be sure all electric devices including the lines and plug connections are in good condition before connection to the...

Page 18: ...altitude for the application of the high altitude carburetor main jet is listed in the following table In order to select the correct high altitude main jet it is necessary to identify the carburetor...

Page 19: ...n the cover screws and remove the maintenance cover 3 Remove oil fill cap dipstick 4 Tilt the generator on its side and allow the oil to drain completely 5 Add oil according to Add Engine Oil in Assem...

Page 20: ...r screen 5 Carefully remove the carbon deposits from the spark arrestor screen with a wire brush 6 Replace the spark arrestor if it is damaged 7 Position the spark arrestor on the muffler and attach b...

Page 21: ...p and clog the carburetor if it isn t used or drained within 2 4 weeks If using the generator within 2 weeks follow the steps according to Stopping the Engine section 1 If not using the generator for...

Page 22: ...use fuel to vaporize resulting in a possible explosion Do not drive on a rough road for an extended period with the washer on board If you must transport the washer on a rough road drain the fuel from...

Page 23: ...hart Capacity 500ml 16 9 fl oz 20 0 20 40 60 Ambient temperature Temperatura ambiente Temp rature ambiante Recommended Oil Type Tipo de aceite recomendado Type d huile recommand 80 100 120 28 9 F C 17...

Page 24: ...odic parts and service to perform well This warranty does not cover repair when normal use has exhausted the life of a part or the equipment as a whole Installation Use and Maintenance This warranty w...

Page 25: ...92001i EU 1900W Rated Portable Inverter Generator 25 EN Parts Diagram...

Page 26: ...olt M5 x 12 1 31 1ZC7DFB06 Engine 79cc 1 32 100033099 0008 Big Flange Bolt M6 x 18 2 33 100131884 Tube Sheath Silicon Resin 1 34 100131883 0001 Fuel Tube L 275mm 1 Part Number Description Qty 35 10009...

Page 27: ...sing Assembly Bottom Black 1 70 100072711 Housing Bottom Black 1 71 100072994 0001 Step Nut M6 6 72 100072710 0001 Rubber Damper 1 73 100011452 0010 Nut M6 4 74 100072712 Foot Bottom Housing 4 75 1000...

Page 28: ...92001i EU 1900W Rated Portable Inverter Generator 28 Engine Parts Diagram...

Page 29: ...ket Cylinder Head 1 33 100010549 Dowel Pin 8 x 12 4 34 100075061 Push Rod 2 35 100075059 Valve Exhaust 1 Part Number Description Qty 36 100159354 Valve Intake 1 37 100075036 Lifter Valve 2 38 10007504...

Page 30: ...Part Number Description Qty 72 100011571 0002 Big Flange Bolt M6 x 14 3 73 100131964 Fuel Bowl Mounting Bolt 1 74 100131960 Fuel Bowl O Ring 1 75 100163552 Main Jet Standard 1 100163549 Main Jet Altit...

Page 31: ...92001i EU 1900W Rated Portable Inverter Generator 31 EN Wiring Diagram...

Page 32: ...he state in which it was placed on the market and excludes components which are added and or operations carried out subsequently by the final user Designation Function Gasoline generating set 1 Type 9...

Page 33: ...e Winch Solutions LTD Address Unit 17 18 Bradley Trading Estate Bradley lane Standish Greater Manchester WN6 0XQ UK 7 Date Place Authorized Signature APRIL 21ST 2020 HANGZHOU LI JIE 8 Title of Signato...

Page 34: ...l 44 0 1942 715 407 technical bpeholdings co uk Germany BPE Solutions Deutschland GmbH Altrottstra e 31 D 69190 Walldorf Germany Tel 49 6227 655996 3 support bpeholdings de Sweden BPE Nordic AB Valn s...

Reviews: