background image

5

ENGLISH

 

500110-N

SAfETy RULES

A

B

E

C

C

D

Safety Label Locations

These labels warn you of potential hazards that can cause serious injury. Read them carefully.

If a label comes off or becomes hard to read, contact Champion Power Equipment’s customer service department for 
possible replacement.

B

C

D

 WARNING

DO NOT TOUCH! 

Exhaust gases, muffler 

and engine components 

are extremely HOT and 

cause burns.

Operation of this equipment may create sparks that can start 

fires around dry vegetation. A spark arrestor may be 

required. The operator should contact local fire agencies for 

laws and regulations relating to fire prevention requirements. 

If installed, clean every 100 hours or every season.

 

 ADVERTENCIA

¡NO TOCAR!

 Los gases de 

escape, el silenciador y los 

compnonentes del motor están 

extremadamente CALIENTES y 

causan quemaduras.

La operación de este equipo puede producir chispas que pueden provocar 

incendios alrededor de la vegetación seca. Un supresor de chispas puede que 

sea necesario. El operador debe comunicarse con las agencias locales de 

bomberos para las leyes y reglamentos relativos a los requisitos de prevención 

de incendios. Si está instalado, limpie cada 100 horas o cada temporada.

 AVERTISSEMENT

NE PAS TOUCHER!

 Les gaz 

d’échappement, le silencieux 

et les pièces du moteur sont 

extrêmement CHAUDS et 

peuvent causer des brûlures.

Cet équipement peut créer des étincelles et provoquer un incendie dans la 

végétation sèche. Un pare-étincelles peut être requis. L’utilisateur doit 

communiquer avec le service d’incendie local pour connaître les lois et 

les règlements en matière de prévention des incendies. Si elle est 

installée, nettoyez la génératrice toutes les 100 heures ou chaque saison.

10

35

-L

-SF-

C

Colors

LPN

1035-L-SF

Rev

C

Size

369 x 26 mm

Artwork Notes

3mm corner radius; 2mm safe margin

Revision Changes

C: updated some FR translation words.

This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for 
outside parties without the explicit consent of Champion Power Equipment.

K

485

152

---

---

A

E

UNLEADED FUEL ONLY. 

Minimum octane

rating of 91. Maximum 10% ethanol.

GASOLINA REGULAR SOLAMENTE.

 

91 octanos

como mínimo. Máximo de etanol de 10%.

ESSENCE SANS PLOMB SEULEMENT.

Indice d’octane minimal de 91.

Maximum 10 % d'éthanol.

K

109

---

---

---

Colors

LPN

Rev

Size

46 x 46 mm

Artwork Notes

3mm corner radius; 2mm safe margin; white to be 

printed shown in 50% process magenta

Revision Changes

-Changed Octane rating from 85 to 87 (20200407)

This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for 
outside parties without the explicit consent of Champion Power Equipment.

CAUTION

A transfer switch MUST be used 

when connecting generator to a 

building’s electrical system.

See Owner’s Manual.

PRECAUCIÓN

Es OBLIGATORIO usar un interruptor de 

transferencia cuando se conecte el generador 

al sistema eléctrico de un inmueble. Vea el 

manual del propietario

MISE EN GARDE

Le commutateur de transfert DOIT être 

utilisé pour connecter la génératrice 

au système électrique d’un immeuble. 

Consulter le manuel du propriétaire.

GN

-S

F-T-

00

2.1

109

BLACK

158 x 23 mm

WHEN STORING GASOLINE, PROPANE (LPG) OR 

EQUIPMENT WITH FUEL IN IT: 

Store away from 

furnaces, stoves, water heaters or other appliances that 

have a pilot light or other ignition source because they 

can ignite the fuel.

FOR USE IN A WEATHER-PROTECTED AREA ONLY.

DO NOT EXPOSE TO RAIN.

Operating of this equipment may create 

sparks that can start fires around dry 

vegetation. A spark arrester may be required. 

The operator should contact local fire 

agencies for laws or regulations relating to fire 

prevention requirements.

Read and follow all operating instructions 

before running engine.

Gasoline and propane (LPG) are extrememely 

flammable. Check for spilled fuel or fuel 

leaks. If one is found, shut off fuel supply and 

stop engine immediately. Allow to cool at 

least 2 minutes before refueling.

FOR ELECTRICAL EQUIPMENT ONLY.

DANGER

WARNING

CAUTION

GN-SF-E-005.1

485

152

109

BLACK

63 x 99 mm

CUANDO ALMACENE GASOLINA, GAS PROPANO 

(GLP) O EQUIPO CON COMBUSTIBLE ADENTRO: 

Almacene fuera de hornos, estufas, calentones de agua, 

o otros aparatos que tengan luz piloto o otra fuente de 

encendido por que pueden encender el combustible.

PARA USO EN AREAS DESPEJADAS SOLAMENTE.

NO EXPONGA A LA LLUVIA.

La operación de este equipo puede originar 

chispas que pueden crear incendios cerca de 

la vegetación seca. Es posible que se requiera 

un parachispas. El operador deberá 

comunicarse con los organismos locales 

encargados de combatir incendios para 

conocer las leyes o reglamentos relacionados 

con los requisitos para prevenir incendios.

Lea y acate todas las instrucciones de 

operación antes de encender el motor.

La gasolina y el gas propano (GLP) son 

extremadamente inflamables. Verifique si 

hay combustible derramado o fugas de 

combustible. Si una es encontrada, apague 

el suministro y pare el motor inmediata-

mente. Permita que se enfrié por los menos 

2 minutos antes de reabastecerlo.

PARA EQUIPOS ELÉCTRICOS SOLAMENTE.

PELIGRO

ADVERTENCIA

PRECAUCIÓN

GN-SF-S-005B.1

485

152

109

BLACK

63 x 110 mm

MINIMU

M C

LEA

RA

NC

E

5 FT.

ESPA

CIO

 M

ÍNI

MO

1,5 M

MI

NI

MU

D'E

SPA

CE

1,5

 M

Summary of Contents for 500110-N

Page 1: ...RATING INSTRUCTIONS SAVE THESE INSTRUCTIONS Important safety instructions are included in this manual REV 500110 N 20210111 9375 Starting Watts 7500 Running Watts PORTABLE GENERATOR Electric Start 500...

Page 2: ...n Fri 8 30 AM 5 00 PM PST PDT Toll Free AN IMPORTANT MESSAGE ABOUT TEMPERATURE Your Champion Power Equipment product is designed and rated for continuous operation at ambient temperatures up to 40 C 1...

Page 3: ...3 Do Not Overload Generator 14 Capacity 14 Power Management 14 Operation at High Altitude 14 Maintenance and Storage 15 Engine Maintenance 15 Oil 15 Spark Plugs 15 Air Filter 15 Spark Arrester 16 Clea...

Page 4: ...e the accuracy and completeness of the information in this manual and we reserve the right to change alter and or improve the product and this document at any time without prior notice Since CPE CET h...

Page 5: ...hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided ma...

Page 6: ...ate generator from your electric utility and Notify your utility company before connecting your generator to your power system DANGER Sparks can result in fire or electrical shock When servicing the g...

Page 7: ...O NOT tamper with the governed speed DO NOT modify the generator in any way CAUTION Fuel and fuel vapors are highly flammable and extremely explosive Fire or explosion can cause severe burns or death...

Page 8: ...hampion Power Equipment The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the explicit consent of Champion Power Equipment CAUTION A...

Page 9: ...to start the engine 3 Fuel Valve Used to turn fuel supply on and off to engine 4 Air Cleaner Protects the engine by filtering dust and debris from the intake air 5 Recoil Starter Used to manually sta...

Page 10: ...d wattage output 3 Circuit Breakers Protects the generator against electrical overloads 4 230 Volt AC 30 Amp May be used to supply electrical power for the operation of 230 Volt AC single phase 50 Hz...

Page 11: ...he following parts Wheel Kit 9 5 in 24 1 cm Wheel 2 Pin Roll 16 x 10 x 107 for Wheel 2 R Shape Pin 2 x 33 2 Support Leg w Vibration Mounts 1 Flange Bolt M8x16 for Support Leg 2 Flange Lock Nut M8 2 Ot...

Page 12: ...wheel kit and support leg Install the Wheel Kit Install the Support Leg 1 Attach the support leg to the generator frame with flange bolts M8x16 and flange lock nuts M8 2 Tip the generator slowly so th...

Page 13: ...ditional lubrication for the life of the bearing NOTE Add Engine Oil Cont d Synthetic oil may be used after the 5 hour initial break in period Using synthetic oil does not increase the recommended oil...

Page 14: ...cture s warranty It is advisable to always shut off the fuel supply run the engine to fuel starvation and drain the tank when the equipment is not in use for more than 30 days NOTE Add Fuel 1 Use clea...

Page 15: ...et could result in electrocution WARNING WARNING During operation the muffler and exhaust fumes produced will become hot If adequate cooling and breathing space are not supplied or if the generator is...

Page 16: ...and codes NOTE Operation Stopping the Engine 1 Turn off and unplug all electrical loads Never start or stop the generator with electrical devices plugged in or turned on 2 Let the generator run at no...

Page 17: ...wrong engine configuration at a given altitude may increase its emissions and decrease fuel efficiency and performance WARNING Operation at High Altitude The density of air at high altitude is lower t...

Page 18: ...4 Saturate in clean engine oil 5 Squeeze in a clean absorbent cloth to remove all excess oil 6 Place the filter in the assembly 7 Reattach the air filter cover and snap in place Spark Plugs 1 Remove t...

Page 19: ...nd local laws and administrative requirements indicate when and where spark arresters are required When ordered spark arresters are required for operation of this generator in National Forest lands In...

Page 20: ...pulling the engine recoil cord If the battery voltage is extremely low the charging circuit may not be able to re charge the battery In this case the battery must be connected to a standard automotive...

Page 21: ...0 028 0 031 in Oil Use 10W 30 automotive oil Oil capacity is up to 1 2 qt 1 1 L DO NOT OVERFILL Please reference the following chart for recommended oil types for use in the generator Specifications...

Page 22: ...ERMINAL SPARK PLUG IGNITION COIL OIL LEVEL SW MW2 CONTROL BOX BLOCK COMBINATION SW W Y Y L L R Br L M Br W W L G Y CHARGE COIL BATTERY STARTER DIODE Br B G B G R B 3 4 2 1 6 5 OFF ON ST COMBINATION SW...

Page 23: ...0 31 32 33 34 35 36 37 38 23 29 39 41 42 16 17 20 1 2 5 6 7 8 9 10 11 12 43 44 45 14 47 48 49 50 51 52 53 54 56 57 58 59 60 61 62 63 18 19 54 64 65 66 67 68 69 71 72 45 73 74 75 76 79 84 85 86 87 88 9...

Page 24: ...00703 04 Long Pin Handle 2 49 1 894 1 08 Circlip 8 2 50 152 200703 02 Short Pin Handle 2 51 152 200701 02 2 Handle U Shape 1 52 152 200702 02 Cover Handle 1 53 65251 0 10 2 Frame 700 x 541 x 600 1 54...

Page 25: ...37 38 36 12 34 35 33 32 29 30 31 28 26 27 12 24 25 99 100 101 97 98 102 103 104 105 106 107 91 112 110 108 109 92 93 94 12 111 85 86 87 88 89 90 91 113 95 96 40 41 42 43 44 45 46 47 48 49 50 51 52 53...

Page 26: ...2 57 2 15 002 F6RTC Spark Plug F6RTC 1 Part Number Description Qty 58 2 08 122 Flange Bolt M10 x 95 4 59 46 020002 00 Gasket Cylinder Head Cover 1 60 47 021000 00 Cover Cylinder Head 1 61 45 020001 02...

Page 27: ...Part Number Description Qty 115 45 040013 00 Lifter Exhaust Valve 1 116 45 125000 03 Starter Motor Assembly 1 117 46 040200 00 Rocker Arm Assembly 1 118 47 010000 01 Cylinder Head Assembly 1 119 1 617...

Page 28: ...erator on a flat level surface Generator cannot supply enough power or overheating Generator is overloaded Review load and adjust See Power Management Insufficient ventilation Check for air restrictio...

Reviews: