201003 - 5500W DUAL FUEL ELECTRIC START INVERTER GENERATOR
OPERATION
23
3. Turn the EZ Start dial to the propane “RUN” position.
4. Press and hold the ignition switch in the “START” position for
3 - 5 seconds.
NOTICE
If the engine is cranked longer than 5 seconds, the engine can
flood and will not start.
5. Repeat Steps 1-4 until the engine starts.
6. When the engine starts, turn the EZ Start dial to the propane
“RUN” position if in the propane “CHOKE” position.
7. Plug in devices.
Manual Start
1. Turn the EZ Start dial to the propane “CHOKE” position.
2. PULL-TO-PRIME: Pull the recoil cord slowly. Pull with 100%
“CHOKE” 1-3 times until you feel a few combustion pulses
that indicates that the engine momentarily started.
3. Move the choke to the “RUN” position.
4. Pull the recoil cord slowly until resistance is felt and then pull
rapidly.
5. If engine fails to start in 3 pulls with the EZ Start dial in the
“RUN” position, then move EZ Start dial to the “CHOKE”
position and repeat the PULL-TO-PRIME step.