201003 - 5500W DUAL FUEL ELECTRIC START INVERTER GENERATOR
CONTROLS AND FEATURES
13
Control Panel
1.
Intelligauge with Power Meter
– See
Intelligauge with
Power Meter
section.
2.
Ignition Switch
3.
EZ Start Dial
– Used to stop the generator and control the
fuel supply and choke.
4.
Recoil Cord
5.
LPG Inlet
– Used to connect LPG fuel source to generator.
6.
Circuit Breakers (Push Reset)
– Protects the generator
against electrical overloads.
7.
Parallel Outlets
– Used to parallel two inverters together for
increased power output. (parallel kit sold separately).
8.
Ground Terminal
– Consult an electrician for local grounding
regulations.
9.
LED Light
RECEPTACLES
A
z
12V DC, 8A (Automotive)
May be used to supply electrical power for
operation of 12 Volt DC, 8 Amp electrical loads.
B
C
(4×) 120V AC, 20A (NEMA 5-20R)
May be used to supply electrical power for
operation of 120 Volt AC, 20 Amp, single phase,
60 Hz electrical loads.
C
t
120V AC, 30A RV (NEMA TT-30R)
May be used to supply electrical power for
operation of 120 Volt AC, 30 Amp, single phase,
60 Hz electrical loads.
WARNING
Do not operate a device while it is plugged into the 12V DC
outlet. When charging a device, do not place on the exhaust
side of the generator. Extreme heat caused by exhaust
can damage the device and cause a potential fire hazard.
Prolonged exposure to engine exhaust can cause serious injury
or death.
1
3
9
8
2
6
4
5
C
7
B
A