200990 - 4500W WIRELESS REMOTE START INVERTER GENERATOR
OPERATION
28
4. If the generator power output is cut off due to an overload
condition indicated by the AC overload blinking light, lower
the load by unplugging one or more items, then press the
AC overload reset button before restarting the generator for
continued normal operation.
Power Management
Use the following formula to convert voltage and amperage to
watts:
Volts × Amps = Watts
To prolong the life of your generator and attached devices, follow
these steps to add electrical load:
1. Start the generator with no electrical load attached.
2. Allow the engine to run for several minutes to get up to
temperature.
3. Plug in and turn on the first item. It is best to attach the item
with the largest load first.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.
NOTICE
Never exceed the specified capacity when adding loads to the
generator.
Eco (Economy) Mode
The Eco Mode button can be activated to turn on economy control
in order to minimize fuel consumption and noise while operating
the unit during times of reduced electrical output. Eco Mode
allows the engine speed to idle during periods of non-use.
The engine speed returns to normal when an electrical load is
connected. When the economy switch is off, the engine runs at
normal speed continuously.
CAUTION
For periods of high electrical load or momentary fluctuations,
the Eco Mode should be off.
Parallel Operation
The Champion model 200990 is parallel ready and can be
operated in parallel with another Champion unit to increase
the total available electrical power. A Champion model 100319
parallel kit (sold separately) is required for parallel operation.
For a list of compatible models or to order a parallel kit, please
call customer service at 1-877-338-0999 or visit www.
championpowerequipment.com.
Detailed instructions for parallel kit installation and operation of
the connected generators are provided in the parallel kit operator’s
manual.
Stopping the Engine
Remote Stop
1. Turn off all electrical connected loads. Never start or stop the
generator with electrical devices turned on.
2. Let the generator run at no-load for several minutes to
stabilize internal temperatures of the engine and generator.