100396 - 3400W Dual Fuel electric Start inverter Generator
StoraGe
30
long term Storage (over 1 year)
For storage over 1 year, the fuel tank and carburetor must be
completely drained of gasoline.
1. Be sure all appliances are disconnected from the generator.
2. Add a properly formulated fuel stabilizer to the fuel tank.
3. Run the generator for 10 minutes so the treated fuel cycles
through the fuel system and carburetor.
4. Run Dry Option:
4a. Let the generator run to fuel complete starvation.
4b. Turn engine switch to the “OFF” position.
4c. Allow generator to cool completely.
5. Drain Fuel Option:
5a. Turn engine switch to the “OFF” position.
5b. Allow generator to cool completely.
5c. Use the drain bolt on the carburetor to completely empty
gasoline from the fuel tank and carburetor into an
appropriate container.
5d. Replace and tighten the carburetor drain bolt.
6. Turn the fuel valve to the “OFF” position.
7. Remove the spark plug and pour about a tablespoon of oil into
the cylinder. Crank the engine slowly to distribute the oil and
lubricate the cylinder.
8. Reattach the spark plug and spark plug cap.
9. If the generator includes a battery, disconnect and charge
according to
Generator Battery
.
10. Clean the generator according to
Generator Maintenance
.
11. Store the generator in a cool, dry place out of direct sunlight.
removing from Storage
notice
If the generator has been improperly stored for a period
longer than 30 days with ethanol blended gasoline in the
gasoline tank and/or carburetor, all fuel must be drained
and the carburetor must be thoroughly cleaned of ethanol
build up. This process involves technically advanced tasks.
For assistance please call our Technical Support Team at
1-877-338-0999.
If the gasoline tank and carburetor were properly emptied of all
ethanol blended gasoline prior to the generator being stored,
follow the below steps when removing from storage.
WarninG
If there is a strong smell of LPG: Close valve on the cylinder.
Check all connections for leaks by wetting the fittings with a
solution of soap and water. Bubbles which appear or bubbles
which grow indicate that a leak exists. Do not smoke or light a
cigarette, or check for leaks using a match, open flame source
or lighter. Contact a qualified technician to inspect and repair
an LPG system if a leak is found, before using the generator.
1. Add fuel to the generator according to
Add Fuel
.
2. With the engine switch in the “OFF” position, turn the
fuel valve to the “ON” position. After 5 minutes check the
carburetor and air filter areas for any leaking gasoline. If
found, the carburetor will need to be disassembled and
cleaned or replaced. If no fuel leaks are found, turn the fuel
valve to the “OFF” position.
3. Check oil level and add clean, fresh oil if needed.
4. Check and clear air filter of any obstructions such as bugs or
cobwebs. If necessary, clean according to
Air Filter section
.
5. If the generator includes a battery, connect according to
Connect the Battery
6. Start the generator according to
Starting the Engine
.