background image

8

10

9

5

NOT

ICE

6

4

3

2

12

13

7

1

11

LOCK

LIGHT

1

2

3

5

4

6

7

Installation Parts

39

REPAIR PARTS

Rail Assembly Parts

KEY

PART

NO. NO.

DESCRIPTION

1

4A1008

Master link kit

2

41C5141-1

Complete trolley assembly

3

41A5665

Complete rail

4

41B4103

Spring trolley nut

5

144C54

Idler pulley

6

41A5250

Full belt assembly

7

12D598-1

“U” bracket

NOT SHOWN

183A163

Wear pads

41A145

Rail clip

KEY

PART

NO.

NO.

DESCRIPTION

1

41C472-7

Motion detecting control panel

2

953D

3-Button remote control

3

10A20

3V 2032 Lithium battery

4

29B137

Visor clip

5

41A2828

Emergency release rope and handle
assembly

6

41B4494-1

2-Conductor bell wire: white and
white/red

7

41A5047-3

Header bracket w/clevis pin and
fastener

8

41A5047-1

Door bracket w/clevis pin and
fastener

9

178B35

Curved door arm section

10

178B34

Straight door arm section

11

12B776

Hanging bracket

12

41A5034

Safety sensor kit: receiving and
sending eyes with 3' (.91 m)
2-conductor bell wire attached

13

41A5266-1

Safety sensor bracket

NOT SHOWN

41A5257-9

Installation hardware bag 
(includes hardware listed on page 7)

114A3056

Owner’s manual

114A3056SP Owner’s manual - Spanish

Summary of Contents for WD952LD

Page 1: ...ner s Manual Please read this manual and the enclosed safety materials carefully Fasten the manual near the garage door after installation The door WILL NOT CLOSE unless The Protector System is connec...

Page 2: ...the trolley 8 Fasten the rail to the motor unit 9 Install the idler pulley 9 Install the belt and attach the belt cap retainer 10 Set the tension 11 Installation 11 26 Installation safety instruction...

Page 3: ...arage door Before you begin Disable locks Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or binding 1 Lift the door...

Page 4: ...upport bracket and additional fastening hardware may be required Installation Step 10 Depending upon garage construction extension brackets or wood blocks may be needed to install sensors Installation...

Page 5: ...nsor Access Door FINISHED CEILING Support bracket fastening hardware is required See page 16 Safety Reversing Sensor Header Wall Gap between floor and bottom of door must not exceed 1 4 6 mm Wall moun...

Page 6: ...Light Lens Belt Cap Retainer Battery Backup Unit Remote Control Transmitter Visor Clip SECURITY 3 Button Remote Control 2 LOCK LIGHT Motion Detecting Door Control Panel SECURITY Keyless Entry Your gar...

Page 7: ...30 Drywall Anchors 2 Clevis Pin 5 16 x1 1 Rope Lock Washer 5 16 7 Lag Screw 5 16 9x1 5 8 2 Hex Bolt 5 16 18x7 8 4 Clevis Pin 5 16 x1 1 4 1 Lag Screw 5 16 18x1 7 8 2 Screw 6ABx1 1 4 2 Screw 6 32x1 2 Cl...

Page 8: ...posite edge about 4 3 4 12 cm from the far end 1 Remove the straight door arm and hanging bracket packaged inside the front rail and set aside for Installation Step 5 and 12 NOTE To prevent INJURY whi...

Page 9: ...w Keep the ribbed side toward the rail and allow it to hang until Assembly Step 5 Remove the tape from the idler pulley The inside center should be pre greased If dry regrease to ensure proper operati...

Page 10: ...h pins are securely locked in place 5 Insert the trolley threaded shaft through the hole in the trolley Be sure the belt is not twisted and the ribbed side faces the rail 6 Hold the belt at the trolle...

Page 11: ...in SEVERE INJURY or DEATH 3 All repairs to cables spring assemblies and other hardware MUST be made by a trained door systems technician BEFORE installing opener 4 Disable all locks and remove all rop...

Page 12: ...of the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 13 for ceiling installation To prevent possible SERIOUS INJU...

Page 13: ...Mark the vertical set of bracket holes do not use the holes designated for ceiling mount Drill 3 16 pilot holes and fasten the bracket securely to a structural support with the hardware provided Lag S...

Page 14: ...der bracket with the two plastic spacers included in the hardware bag Place the spacers inside the bracket on each side of the rail as illustrated Position the opener on the garage floor below the hea...

Page 15: ...or setting an ideal door to rail distance Remove foam packaging Raise the opener onto a stepladder You will need help at this point if the ladder is not tall enough Open the door all the way and place...

Page 16: ...6 Check to make sure the rail is centered over the door or in line with the header bracket if the bracket is not centered above the door 7 Remove the 2x4 Operate the door manually If the door hits the...

Page 17: ...ure Adjust screw for snug fit Drill and install top screw with care to avoid cracking plastic housing Do not overtighten Insert top tabs and snap on cover 3 For standard installation only Run bell wir...

Page 18: ...release arm of the outer trolley Adjust rope length so the handle is 6 feet 1 81 m above the floor Ensure that the rope and handle clear the tops of all vehicles to avoid entanglement Secure with an o...

Page 19: ...he black line wire to the screw on the brass terminal the white neutral wire to the screw on the silver terminal and the ground wire to the green ground screw The opener must be grounded Reinstall the...

Page 20: ...r Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens The mounting brackets are designed to clip onto the track of sectional g...

Page 21: ...p hugging the back edge of the track as shown in Figure 1 If your door track will not support the bracket securely wall installation is recommended Wall installation Figure 2 3 Place the bracket again...

Page 22: ...beam path is not obstructed alignment is required Loosen the sending eye wing nut and readjust aiming directly at the receiving eye Lock in place Loosen the receiving eye wing nut and adjust sensor u...

Page 23: ...re the door bracket using the two 1 4 14x5 8 self threading screws Figure 2A Alternately use two 5 16 bolts lock washers and nuts not provided Figure 2B Metal insulated or light weight factory reinfor...

Page 24: ...he door if required for your installation Refer to the dotted line optional placement drawing Header Wall Vertical Centerline of Garage Door Finished Ceiling Optional Placement of Door Bracket Header...

Page 25: ...are above holes in straight arm disconnect straight arm Cut about 6 15 cm from the solid end Reconnect to trolley with cut end down as shown Bring arm sections together Find two pairs of holes that l...

Page 26: ...the trolley using the 5 16 x1 1 4 clevis pin and ring fastener NOTE Adjusting the limits on the following page The trolley will automatically connect If not review the trolley lockout feature on page...

Page 27: ...il rail should not bow upwards and the belt should not sag or droop below the rail Push the remote control or door control Figure 3 This sets the DOWN close limit and begins opening the door Without a...

Page 28: ...will stop flashing when the force has been learned The unit has learned the forces required to open and close your door The door must travel through a complete cycle UP and DOWN in order for the force...

Page 29: ...est adjustment If the unit continues to fail the Safety Reverse Test call for a trained door systems technician IMPORTANT SAFETY CHECK Test the Safety Reverse System after Each adjustment of door arm...

Page 30: ...eature on the Motion Detecting Control Console is activated Bulb size is 100 watts maximum Security light feature Lights will also turn on when someone walks through the open garage door With a Motion...

Page 31: ...e 4 1 2 minute interval can be changed to 1 1 2 2 1 2 or 3 1 2 minutes as follows Press and hold the Lock button until the light blinks about 10 seconds A single blink indicates that the timer is rese...

Page 32: ...ort After the motor unit has been installed position the BBU above the motor unit to a structural support joist within BBU s cord length of 3 91 m Figure 2 Attach the BBU to the support by using the c...

Page 33: ...r unit power cord from the electrical outlet A solid yellow LED indicates the BBU is operating on battery power A flashing yellow LED with beep indicates the BBU is operating on battery power and that...

Page 34: ...to pry open the case as shown Insert battery positive side up Dispose of old battery properly NOTICE To comply with FCC and or Industry Canada rules IC adjustment or modifications of this receiver an...

Page 35: ...e motor unit then refer to the Diagnostic Chart on the following page 2 My remotes will not activate the door Verify your door control is not blinking If it is blinking deactivate the Lock Mode follow...

Page 36: ...n wire replace as needed Disconnect wires at door control touch wires together If motor unit activates replace door control If motor unit does not activate disconnect door control wires from motor uni...

Page 37: ...NTROL PANEL PROGRAMMING 37 Your garage door opener has already been programmed at the factory to operate with your hand held remote control The door will open and close when you press the large push b...

Page 38: ...ink once when the PIN has been learned Test by pressing the new PIN then press ENTER The door should move To set a temporary PIN You may authorize access by visitors or service people with a temporary...

Page 39: ...Button remote control 3 10A20 3V 2032 Lithium battery 4 29B137 Visor clip 5 41A2828 Emergency release rope and handle assembly 6 41B4494 1 2 Conductor bell wire white and white red 7 41A5047 3 Header...

Page 40: ...5806 DC motor wire harness 41C5418 Light socket wire harness 5 41D605 1 Motor 80kg 100kg 6 41DB001 Receiver logic board assembly with end panel KEY PART NO NO DESCRIPTION 7 41B5351 7 Power supply 8 41...

Page 41: ...when it detects a person entering the garage Sensor can be easily deactivated when desired 3 Button Mini Remote Control with SECURITY With key ring and fastening strip 956D 940D 10 Foot 3 m Rail Exte...

Page 42: ...42 NOTES...

Page 43: ...43 NOTES...

Page 44: ...pt with any product returned for warranty repair Products returned to Seller for warranty repair which upon receipt by Seller are confirmed to be defective and covered by this limited warranty will be...