10
STEP 2
INSTALL THE OPERATOR
Check the national and local building codes before installation.
1. Install the electrical conduit.
2.
Pour a concrete pad (reinforced concrete is recommended). The concrete pad should be 6 inches above the ground and deeper than the frost line.
3. Attach the operator to the concrete pad with appropriate fasteners.
4 Concrete Anchors
1/2" x 3 1/2"
Below the frost
line. Check all
national and
local codes.
6" Above Ground
24" (61 cm)
24" (61 cm)
INSTALLATION
MOUNTING FOOTPRINT
10.4"
(26.4 cm)
10.3" (26.2 cm)
POST MOUNT
An alternative to a concrete pad is to post mount the
operator.