The following spare parts are available:
041AGW45 strap spool for strap lengths up to 4.5m (fig.18)
041AGW10 large strap spool for strap lengths up to 10m (fig.19)
041AGW01 removable control panel (fig.20)
19
18
20
Direct connection to mains supply (optional):
Attention: This work should be done by a skilled worker! Pull plug before opening!
The shutter strap motor may be connected directly to the mains supply. Open the cover at the back of
the control panel using a tool, e.g. a screw driver (fig.21). Loosen both screws of the connection clamp
with a screw driver (fig.22). Now remove the screw of the strain relief and extract the cable. Now put the
phase- and neutral-wire of the mains in both of the left clamps (random order) and reinsert both of the
clamp screws. Put the cable back into the strain relief and tighten screw again using a screw driver
(fig.23).
21
22
23
709156-1GB
G
B
-6