Once a Month: 

• Repeat safety reverse test. Make any necessary adjustments.

• Manually operate door. If it is unbalanced or binding, call for

professional garage door service.

• Check to be sure door opens and closes fully. Set Limits and/or

Force if necessary.

Once a Year:

Oil door rollers, bearings and hinges. The opener does not require
additional lubrication. Do not grease the door tracks. Grease rail and
trolley once a year.

When properly installed, opener will provide high performance with
a minimum of maintenance. The opener does not require additional
lubrication.

Limit and Force Settings: These settings must be checked and
properly set when opener is installed. Weather conditions may cause
some minor changes in the door operation, requiring some 
re-adjustments, particularly during the first year of operation.

Refer to Setting the Limits and Force on page 5. Follow the
instructions carefully and repeat the safety reverse test after
any adjustment.

Remote Control: The remote control may be secured to a car sun
visor with the clip provided. Additional remotes can be purchased at
any time for use in all vehicles using garage. Refer to Accessories.
Any new remotes must be programmed into the opener.

Remote Control Battery: The lithium batteries should produce power
for up to 5 years. If transmission range lessens, replace battery.

To Change Battery: To replace batteries, use the visor clip or
screwdriver blade to pry open the case. Insert batteries positive side
up
. To replace cover, snap shut along both sides. Do not dispose of
the old battery with household waste. Take batteries to a proper
disposal center.

MAINTENANCE OF YOUR OPENER

CARE OF YOUR OPENER

OPERATION OF YOUR OPENER

Your opener can be activated by any of the following devices:

• The Lighted Door Control Button. Hold the button down until door

starts to move.

• The Outside Keylock or Keyless Entry System (if you have

installed either of these accessories). 

• The Remote Control Transmitter. Hold the push button down until

the door starts to move.

Opening the Door Manually:

Door should be fully closed if possible. Weak or broken springs
could allow an open door to fall rapidly. Property damage or
serious personal injury could result.

The door can be opened manually by pulling the release handle down
and back (toward the opener). To reconnect the door, pull the release
handle straight down.

Do not use the manual release handle to pull the door opener
or closed.

When the Opener is Activated by Remote Control or Lighted Door
Control Button:

1. If open, the door will close. If closed, the door will open.

2. If closing, the door will stop. 

3. If opening, the door will stop (allowing space for entry and exit of

pets and for fresh air).

4. If the door has been stopped in a partially open or closed position, it

will reverse direction. 

5. If an obstruction is encountered while closing, the door will reverse.

6. If an obstruction is encountered while opening, the door will reverse

and stop. 

7. The optional Protector System™ uses an invisible beam which,

when broken by an obstruction, causes a closing door to open
and prevents an open door from closing. It is STRONGLY
RECOMMENDED for homeowners with young children.

Allow a 15 minute cooling period after 5 continuous operations
of the opener.

The opener light will turn on: 1. when opener is initially plugged in;
2. when the power is briefly interrupted; 3. when the opener is
activated. 

The light turns off automatically after 2-1/2 minutes. Bulb size is
24V/21W maximum.

114A2804E-GB

Summary of Contents for ML700-GB

Page 1: ...L750 GB and ML850 GB GB GB 0800 317847 i 114A2804E GB WARNING DAMAGE MAY OCCUR TO DOOR OR OPERATOR IF IR PROTECTOR SYSTEM IS NOT INSTALLED PROTECTOR SYSTEM MUST BE INSTALLED FOR PROPER FUNCTIONING OF...

Page 2: ...wear rings watches or loose clothing while installing or servicing a garage door opener To avoid serious personal injury from entanglement remove all ropes connected to the garage door before install...

Page 3: ...th stop 3 on top of opener Wrap chain belt 4 over sprocket 5 Push idler pulley bracket assembly toward front of the rail to eliminate excess slack in chain belt Align bolt holes on brackets 6 with bol...

Page 4: ...levis pin 6 It may be necessary to lift the door slightly to make the connection Secure with ring fastener 7 NOTE When setting the up limit the door should not have a backward slant when fully open A...

Page 5: ...he Protector System provides an additional measure of safety against a small child being caught under a garage door It uses an invisible beam which when broken by an obstruction causes a closing door...

Page 6: ...nd remote control transmitter are set to a matching code If you purchase additional remote controls the garage door opener must be programmed to accept the new remote code Program the Receiver to Matc...

Page 7: ...of the Having a Problem section and follow the instructions for setting the limits manually 25 ADJUSTMENT SECTION Setting the Force The force setting button is located behind the light lens of the op...

Page 8: ...cm on either side of the door s centerline For one piece doors without track B position lock 35 60cm below top of door For all other door types A C and D position the lock 50 75cm below the top of the...

Page 9: ...operate from either door control or remote Does the opener have electric power Plug lamp into outlet If it doesn t light check the fuse box or the circuit breaker Some outlets are controlled by a wal...

Page 10: ...ENER CARE OF YOUR OPENER OPERATION OF YOUR OPENER Your opener can be activated by any of the following devices The Lighted Door Control Button Hold the button down until door starts to move The Outsid...

Page 11: ...Adjustable door arm Pull cord trolley release Safety Personal Push button and automatic reversal in down direction Push button and automatic stop in up direction Electronic Automatic force adjustment...

Page 12: ...ress or implied warranty relating to this product No representative or person is authorized to assume for Chamberlain any other liability in connection with the sale of this product GB Other Requireme...

Page 13: ...Illustrations Garage Door Operator Model ML700 GB ML750 GB and ML850 GB GB 114A2884D GB 0800 317847 i...

Page 14: ...2 A B E C D 114A2884D 1 2 1 10 mm 8 mm 4 5 mm 4 mm 11mm 13mm 2...

Page 15: ...10 19 7 9 3 4 5 6 12 13 8 NOTICE 11 2 15 14 17 18 1 20 16 21 22 23 3 3 114A2884D 1 2 3 12 4 5 9 7 10 11 13 14 6 8 15 10 4...

Page 16: ...4 114A2884D 2 3 4 5 1 2 5 A 7 B 6 8 1 2 5 3 4 6...

Page 17: ...5 114A2884D 1 3 2 1 3 2 8 1 2 3 4 5 7 5 4 6 7...

Page 18: ...6 114A2884D 3 5 2 4 6 1 7 6 3 2 1 8 11 3 1 6 7 2 5 4 10 3 1 4 6 7 2 5 4 7 6 3 1 6 2 1 6 2 3 4 4 5 5 3 3 5 9...

Page 19: ...7 114A2884D 2 50mm 2 3 1 4 B A 3 6 150mm 6 1 2 3 5 5 5 5 5 5 5 13 3 1 2 4 12...

Page 20: ...8 114A2884D A C 3 1 2 2 5 1 2 3 1 B 2 4 1 3 3 2 5 2 3 6 6 6 16 1 15 1 2 2 1 14...

Page 21: ...9 114A2884D 2 3 4 NOTICE 2 1 17 19 2 1 24V 21W Max 18 1 2 A B 1 4 C 1 2 3 3 1 2 4 3 4 20 7 6 2 9 1 8 4 5 3 A 4 3 5 B 7 6 6 1 2 6 4 5 7 3...

Page 22: ...4 2 3 1 WHT 2 RED 1 5 6 6mm 1 2 4 WHT RED 1 4 LOCK LIGHT 3 3 2 3 10 114A2884D 21 1 LOCK LIGHT 2 3 21A 4...

Page 23: ...11 114A2884D 1 2 3 A 2 1 B C 3 2 1 1 1 D 2 3 6 7 16 11 mm 5 4 Attach with Concrete Anchors Not Provided Attach with Concrete Anchors Not Provided 3 4 22...

Page 24: ...12 114A2884D 1 3 2 7 6 LOCK LIGHT 5 LOCK LIGHT 4 24 1 3 2 7 6 LOCK LIGHT 5 LOCK LIGHT 4 23...

Page 25: ...2 2 2x 3 4 13 26 1 2 3 1 2 3 4 25 1 27 114A2884D...

Page 26: ...14 A B 8 7 6 5 28 114A2884D A 29 50 75cm 4 5 1 2 3 6 4 50 75cm 5 3 1 2 6 35 60cm 4 6 3 1 2 5 1 2 3 4 2 6 5 8 6 1 7 3 2 5 4 6 3 4 5 1 2 50 75cm A B C D 19mm 6 5mm 38mm E F G...

Page 27: ...b Cd Hg 12B380 12C778 41A5800 12C788 183D177 183D178 41A5887 41A5060 10 10A20 216A206 31D536 41A5799 12C772 31D533 41A5843 210C42 12C777 144C77 146A112 31 9 6 8 7 5 845EML 1703EML 770EML 1702EML 760EM...

Page 28: ...41A589 1 158A49 41A5797 41A5734 2 111A79 41C161 1 ML700 ML750 41C162 2 ML850 41D577 41A5828 ML700 41A5828 1 ML750 41A5828 2 ML850 108C82 41A5908 2004 Chamberlain GmbH 114A2884D All rights reserved 32...

Reviews: