IMPORTANT SAFETY INSTRUCTIONS

To reduce the risk of SEVERE INJURY or DEATH:

WARNING

WARNING

1. READ AND FOLLOW ALL WARNINGS AND

INSTRUCTIONS.

2. ALWAYS keep transmitters out of reach of children.

NEVER permit children to operate or play with the

wireless wall button, multi-fucntion door control or

transmitters.

3. ONLY activate the door when it can be seen clearly,

it is properly adjusted and there are no obstructions

to door travel.

4. ALWAYS keep the door in sight until completely

closed. NO ONE SHOULD CROSS THE PATH OF THE

MOVING DOOR.

5. NO ONE SHOULD GO UNDER A STOPPED,

PARTIALLY OPENED DOOR.

6. If possible, use emergency release handle to

disengage door ONLY when the door is CLOSED.

Weak or broken springs or unbalanced door could

result in an open door falling rapidly and/or

unexpectedly.

7. NEVER use emergency release handle unless the

doorway is clear of persons and obstructions.

8. After ANY adjustments are made, the safety

reversal system MUST be tested.

9. Safety reversal system MUST be tested every

month. The door MUST reverse on contact with

40mm (1 1/2”) high obstacle on the floor.

10. ALWAYS KEEP THE DOOR PROPERLY BALANCED

(see page 3). An improperly balanced door may

not reverse when required and could result in

SEVERE INJURY or DEATH.

11. ALL repairs to cables, spring assemblies and other

hardware, ALL of which are under EXTREME

tension, MUST be made by a trained door systems

technician.

12. ALWAYS disconnect electric power to the door

opener BEFORE making ANY repairs or removing

covers.

13. Permanently fix the Emergency release instruction

Label adjacent to the release handle.

14.

SAVE THESE INSTRUCTIONS.

EMERGENCY DOOR RELEASE

ADJUSTMENT STEP 7

To Open the Door Manually

Disengage door lock before proceeding. The door should be fully

closed if possible. Pull down on the emergency release handle

until a click noise is heard from the unit and lift the door

manually. To reconnect the door to the opener, pull down the

emergency release handle straight down a second time until a

click noise is heard from the unit. The door will reconnect on the

next UP or DOWN operation.

Test the emergency release:

• Make sure the door is closed.
• Pull the emergency release handle. The door should then be

able to be opened manually.

• Return the door to the closed position.
• Pull the emergency handle a second time.
• Reconnect the door to the opener.

NOTICE

Emergency
Release Handle

WARNING

To prevent possible SERIOUS INJURY or DEATH from a falling door:

• If possible, use emergency release handle to disengage door ONLY when door is CLOSED. Weak or

broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.

• NEVER use emergency release handle unless the doorway is clear of persons and obstructions.

Powered Door Lock

Manual Releas

Lock Bolt
“Locked”

Summary of Contents for Merlin MJ3800

Page 1: ...rating Instructions Optional Accessory Available See Page 10 for the New www chamberlainanz com Owners Copy Please keep these instructions for future reference This manual contains IMPORTANT SAFETY in...

Page 2: ...damage Read and follow all instructions carefully The garage door opener is designed and tested to offer safe service provided it is installed and operated in strict accordance with the instructions i...

Page 3: ...n one carton which contains the opener and the parts illustrated below Note that accessories will depend on the model purchased If anything is missing carefully check the packing material 5 3 1 10 11...

Page 4: ...just door door springs cables pulleys brackets or their hardware ALL of which are under EXTREME tension Disable ALL locks and remove ALL ropes connected to the door BEFORE installing and operating the...

Page 5: ...side that meets the requirements listed below Must have minimum of 64mm 2 1 2 between the wall and the center of the torsion bar Must have minimum of 76mm 3 between the ceiling and the center of tors...

Page 6: ...ted 6 Collar Screw Collar Screw Set Screw Collar Screw Collar Screw Set Screw ASSEMBLY STEP 2 Attach Mounting Bracket to Opener Loosely attach slotted side of mounting bracket to the same side of the...

Page 7: ...all a trained door systems technician if the door binds sticks or is out of balance An unbalanced door might not reverse when required Opener MUST be mounted at a right angle to the torsion bar to avo...

Page 8: ...6 Plug connector into the opener Figure 2 NOTE Lock must be mounted within 3m 10 of the power head Overhand Knot Emergency Release Handle Overhand Knot Rope Opener Emergency Release Cable 016 Warning...

Page 9: ...osite side of the cable tension monitor 1 Position the cable tension monitor as shown Figures 1 and 2 The cable tension monitor should be located as close to the drum as possible NOTE There must be no...

Page 10: ...adjacent the wall controller Fix the emergency door release label adjacent to the opener INSTALLATION STEP 7 Mounting the Evercharge Standby Power Unit SPU not provided If the optional CM475 Standby p...

Page 11: ...ing nut Run wires from both sensors to the opener as shown in Figure 5 Use insulated staples to secure the wire to the wall and ceiling Connect both sets of wires to the opener terminals as shown page...

Page 12: ...ner quick connect terminals white to white and white black to grey Figure 6 page 11 TROUBLESHOOTING THE SAFETY REVERSING SENSORS 1 If the sending eye indicator LEDs are both flashing after installatio...

Page 13: ...AUTOMATIC CLOSE TIMER FUNCTION Note Requires the Chamberlain Protector SystemTM IR sensors to be installed If Protector SystemTM IR sensors is installed only to enable the timer to close function firs...

Page 14: ...button until the door reaches the desired UP open position Figure 2 NOTE Check to be sure the door opens high enough for your vehicle to pass under 3 Push the transmitter wireless wall button or multi...

Page 15: ...reparing your door Orange Button Indicator Light Black Button BLACK ORANGE Push Orange button twice to enter unit into Force Adjustment Mode Figure 3 Figure 2 Figure 1 or Without a properly installed...

Page 16: ...ustment Steps 1 and 2 Programming the Limits and Forces Repeat the test When the door reverses on the 40mm 1 1 2 obstacle remove the obstruction and run the opener through 3 or 4 complete travel cycle...

Page 17: ...emblies and other hardware ALL of which are under EXTREME tension MUST be made by a trained door systems technician 12 ALWAYS disconnect electric power to the door opener BEFORE making ANY repairs or...

Page 18: ...ilable with this accessory Once you have enrolled your users into the C379 you can program the unit into your opener Using the orange LEARN button 1 Press and release the orange learn button 1 on open...

Page 19: ...this temporary PIN will work press the number of hours up to 255 then press star button OR 3 To set the number of times this temporary PIN will open door press the number of times up to 255 then pres...

Page 20: ...n 3 C77 Protector systemTM IR Beams 4 041A6388 Collar with set screws 5 C945 3ch rolling code transmitter 6 041A4582 Emergency release rope handle assembly 041B4494 1 2 Conductor bell wire white white...

Page 21: ...pener does not activate disconnect multi function door control wires from opener Momentarily short across red and white terminals with jumper wire If opener activates replace multi function door contr...

Page 22: ...sensor See Installation Step 8 If the opener LED is not flashing and it is a new installation See Adjustment Step 2 For an existing installation see below Repeat the safety reverse test after the adju...

Page 23: ...ve The wireless wall button CM128 press and hold the large round button down until the door starts to move The Keyless Entry See Accessories Must be programmed before use See Programming Multi Functio...

Page 24: ...eglect abuse wear and tear accident electrical storm excessive use or conditions other than normal domestic use This warranty does not cover any problems with or relating to the garage door or garage...