10

To prevent possible SERIOUS INJURY or DEATH from
electrocution or fire:

• Be sure power is not connected to the opener, and

disconnect power to circuit BEFORE removing cover.

• Door installation and wiring MUST be in compliance

with ALL local electrical and building codes.

• NEVER use an extension cord, 2-wire adapter or alter the

plug in any way to make it fit outlet. Be sure the opener is
grounded.

• If the supply cord is damaged, it must be replaced

by the manufacturer or it’s service agent or a

similiarly qualified person in order to avoid harzard.

+

INSTALLATION STEP 6

Installing the Wireless Wall button (CM128)

Control must be mounted out of the reach of children

at a height of 1.5m with an unobstructed view of the

door.

• Ensure your MJ3800 opener is switched off whilst

installing your wireless door control to prevent

accidental activation.

• Remove the cover from the CM128.

• Mount CM128 as shown using the screws

provided if mounting into a wall box (not

provided).

• If mounting directly on the wall use wall anchors

(provided) to fix unit to the plasterboard wall.

• Replace the cover plate and

affix the warning label

adjacent the wall controller.

Fix the emergency door release label adjacent to the

opener.

INSTALLATION STEP 7

Mounting the Evercharge Standby Power

Unit (SPU)

(not provided)

If the optional CM475 Standby power supply unit is

part of this installation it should be installed at this

time.
• The SPU can be mounted to either the ceiling or

a wall within 3' (.9 m) of the opener.

• Position the SPU as desired to a structural

support (ceiling joist or wall stud).

• Attach the SPU to the support using the

mounting holes on either side of the SPU.

• Secure the SPU using the 1-1/2" lag screws (2)

provided with the SPU unit.

• Connect the SPU cord into the connector on the

bottom of the opener.

• Follow all instructions included with the CM475

unit to test for proper operation and testing of

the SPU.

SPU Cord

Connector

CM475 EverCharge
Standby Power Unit

TM

Disconnect power to the opener whilst installing

this accessory to prevent accidental activation.

Locate minimum 1.5m above the floor.

NOTE: The wireless wall button supplied with your opener should be preprogrammed by the

factory. If adding a new wireless wall button, program into the opener before mounting the unit.

CONNECT ELECTRIC POWER

TO AVOID INSTALLATION DIFFICULTIES, DO NOT RUN

THE GARAGE DOOR OPENER UNTIL INSTRUCTED TO

DO SO.

Connect to properly fused and earth power outlet.

Summary of Contents for Merlin MJ3800

Page 1: ...rating Instructions Optional Accessory Available See Page 10 for the New www chamberlainanz com Owners Copy Please keep these instructions for future reference This manual contains IMPORTANT SAFETY in...

Page 2: ...damage Read and follow all instructions carefully The garage door opener is designed and tested to offer safe service provided it is installed and operated in strict accordance with the instructions i...

Page 3: ...n one carton which contains the opener and the parts illustrated below Note that accessories will depend on the model purchased If anything is missing carefully check the packing material 5 3 1 10 11...

Page 4: ...just door door springs cables pulleys brackets or their hardware ALL of which are under EXTREME tension Disable ALL locks and remove ALL ropes connected to the door BEFORE installing and operating the...

Page 5: ...side that meets the requirements listed below Must have minimum of 64mm 2 1 2 between the wall and the center of the torsion bar Must have minimum of 76mm 3 between the ceiling and the center of tors...

Page 6: ...ted 6 Collar Screw Collar Screw Set Screw Collar Screw Collar Screw Set Screw ASSEMBLY STEP 2 Attach Mounting Bracket to Opener Loosely attach slotted side of mounting bracket to the same side of the...

Page 7: ...all a trained door systems technician if the door binds sticks or is out of balance An unbalanced door might not reverse when required Opener MUST be mounted at a right angle to the torsion bar to avo...

Page 8: ...6 Plug connector into the opener Figure 2 NOTE Lock must be mounted within 3m 10 of the power head Overhand Knot Emergency Release Handle Overhand Knot Rope Opener Emergency Release Cable 016 Warning...

Page 9: ...osite side of the cable tension monitor 1 Position the cable tension monitor as shown Figures 1 and 2 The cable tension monitor should be located as close to the drum as possible NOTE There must be no...

Page 10: ...adjacent the wall controller Fix the emergency door release label adjacent to the opener INSTALLATION STEP 7 Mounting the Evercharge Standby Power Unit SPU not provided If the optional CM475 Standby p...

Page 11: ...ing nut Run wires from both sensors to the opener as shown in Figure 5 Use insulated staples to secure the wire to the wall and ceiling Connect both sets of wires to the opener terminals as shown page...

Page 12: ...ner quick connect terminals white to white and white black to grey Figure 6 page 11 TROUBLESHOOTING THE SAFETY REVERSING SENSORS 1 If the sending eye indicator LEDs are both flashing after installatio...

Page 13: ...AUTOMATIC CLOSE TIMER FUNCTION Note Requires the Chamberlain Protector SystemTM IR sensors to be installed If Protector SystemTM IR sensors is installed only to enable the timer to close function firs...

Page 14: ...button until the door reaches the desired UP open position Figure 2 NOTE Check to be sure the door opens high enough for your vehicle to pass under 3 Push the transmitter wireless wall button or multi...

Page 15: ...reparing your door Orange Button Indicator Light Black Button BLACK ORANGE Push Orange button twice to enter unit into Force Adjustment Mode Figure 3 Figure 2 Figure 1 or Without a properly installed...

Page 16: ...ustment Steps 1 and 2 Programming the Limits and Forces Repeat the test When the door reverses on the 40mm 1 1 2 obstacle remove the obstruction and run the opener through 3 or 4 complete travel cycle...

Page 17: ...emblies and other hardware ALL of which are under EXTREME tension MUST be made by a trained door systems technician 12 ALWAYS disconnect electric power to the door opener BEFORE making ANY repairs or...

Page 18: ...ilable with this accessory Once you have enrolled your users into the C379 you can program the unit into your opener Using the orange LEARN button 1 Press and release the orange learn button 1 on open...

Page 19: ...this temporary PIN will work press the number of hours up to 255 then press star button OR 3 To set the number of times this temporary PIN will open door press the number of times up to 255 then pres...

Page 20: ...n 3 C77 Protector systemTM IR Beams 4 041A6388 Collar with set screws 5 C945 3ch rolling code transmitter 6 041A4582 Emergency release rope handle assembly 041B4494 1 2 Conductor bell wire white white...

Page 21: ...pener does not activate disconnect multi function door control wires from opener Momentarily short across red and white terminals with jumper wire If opener activates replace multi function door contr...

Page 22: ...sensor See Installation Step 8 If the opener LED is not flashing and it is a new installation See Adjustment Step 2 For an existing installation see below Repeat the safety reverse test after the adju...

Page 23: ...ve The wireless wall button CM128 press and hold the large round button down until the door starts to move The Keyless Entry See Accessories Must be programmed before use See Programming Multi Functio...

Page 24: ...eglect abuse wear and tear accident electrical storm excessive use or conditions other than normal domestic use This warranty does not cover any problems with or relating to the garage door or garage...

Reviews: