DIAGNOSTIC CHART

Your garage door opener is programmed with self-diagnostic capabilities. The indicator LEDʼs 1 & 3 on the control panel will flash a number of

times to indicate a fault code exists.

DIAGNOSTIC CODE

LED 1

LED 3

1

1

1

2

1

3

1

4

1

5

2

1

2

2

2

4

4

1

4

2

SYMPTOM

The garage door opener will not

close and the courtesy light flashes.

The garage door opener will not

close and the courtesy light flashes.

The door control will not function.

The garage door opener will not

close and the courtesy light flashes.

There is no door movement or motor

accelerates before stopping

suddenly.

Opener fails to operate.

Opener fails to operate.

Opener fails to operate using the

remote controls

Door is moving down, stops and

reverses.

Door is moving up, stops and

reverses.

POSSIBLE RESOLUTION

Safety sensors are open circuit or wires may be cut. Inspect sensor wires for a

disconnected or cut wire. Turn power off and reboot the opener.

There is a short circuit wire for the safety sensors. Inspect safety sensor wire

at all staple points and replace wire or correct as needed. Turn power off and

reboot the opener.

The wires for the door control are shorted or the door control is faulty. Inspect

safety sensor wire at all staple points and connection points and replace wire

or correct as needed.

Safety sensors are misaligned or were momentarily obstructed. Realign both

sensors to ensure both LEDs are steady and not flickering. Make sure nothing

is hanging or mounted on the door that would interrupt the sensors path while

closing.

No RPM pulses have been detected. Check the door manually for balance,

binding or obstructions. Internally the possible cause may be the motor, logic

board or RPM sensor. Try resetting door travel limits. Contact service centre.

Possible PCB memory failure. Reboot opener by turning the mains power OFF

and then ON after 15 seconds. Reprogram the door travel limits and force

settings. Contact service centre.

Possible PCB Voltage failure. Reboot opener by turning the mains power OFF

and then ON after 15 seconds. Reprogram the door travel limits and force

settings. Contact service centre.

Possible receiver failure. Reboot opener by turning the mains power OFF and

then ON after 15 seconds. Recode the transmitters. Contact service centre.

Manually open and close the door. Check for binding or obstructions, such as

a broken spring or door lock. If the door is binding or sticking contact a trained

door systems technician. If door is not binding or sticking, reset the limits (refer

to “Program the Travel Limits and Force” section).

Manually open and close the door. Check for binding or obstructions, such as

a broken spring or door lock. If the door is binding or sticking contact a trained

door systems technician. If door is not binding or sticking, reset the limits (refer

to “Program the Travel Limits and Force” section).

27

DECLARATION OF CONFORMITY

The manual consists of the operating instructions and the declaration of conformity.

28

114A5144A

© 2018 Chamberlain Group

TM

Trademark of Chamberlain Group

® Registered Trademark of Chamberlain Group

Summary of Contents for LM750EVGB

Page 1: ...ing Garage Door Opener Installation and Operating Instructions Keep these instructions for future reference LM750EVGB Chamberlain GmbH Alfred Nobel Strasse 4 66793 Saarwellingen Germany www liftmaster...

Page 2: ...rier on the ground the garage door MUST return Failure to properly adjust the door opener can result in serious personal injury from a closing garage door Repeat test once a month and make any needed...

Page 3: ...14 OPERATING YOUR OPENER 15 CARE OF YOUR OPENER 15 MAINTAINING YOUR OPENER 15 SPECIFICATIONS 15 ACCESSORIES 16 TROUBLESHOOTING 17 DIAGNOSTIC CHART 18 DECLARATION OF CONFORMITY 18 These instructions a...

Page 4: ...rtain to the edge of the bracket If the roller door drum wheel is on the edge of the curtain or is a smaller diameter additional clearance may be required Assemble the opener to the door axle and the...

Page 5: ...d Diagnostic code indicator Number 1 2 Program UP indicator 3 Diagnostic code indicator Number 2 7 Control Button Used to activate the door when remote controls are not available Open Stop Close 8 Cou...

Page 6: ...ected to the garage door Lift the door to about halfway and then release it The door should remain spring balanced Raise and lower the door to determine if there are any sticking or binding points 20...

Page 7: ...r is installed the handle should be no higher then 1 8 metres from the floor The cord may need to be extended for high door installations Do not disengage the opener to manual operation with children...

Page 8: ...les into the drive legs Align the holes on the extension poles with the holes on the drive legs Using the screws provided secure the extension poles Align the holes of the reinforcing brace with the t...

Page 9: ...le U Bolt and door mounting bracket from the wall Install the opener Slide the opener over the door axle and engage the drive legs into the door drum wheel either side of a spoke Refit the door mounti...

Page 10: ...il LED 3 will flash as well as LED 2 or LED 1 will flash For Right Hand setting LED 2 will flash and for Left Hand setting LED 1 will flash 2 To change to the opposite setting simply press the S butto...

Page 11: ...ting refer to section 14 Repeat the safety reverse system test 15 40 mm Test obstacle 40 mm 16 TESTING THE SAFETY REVERSE SYSTEM After installing the operator on the door the force measurement of the...

Page 12: ...h press DN button will reduce the count if needed Press and release the P button to accept this setting To deactivate the Timer to Close Start with the door fully CLOSED Press and Hold both P and DN b...

Page 13: ...ntilation mode 1 Start with the door fully CLOSED figure 1 Drive the opener UP and stop at the position required for you wish to set the door at 2 Enter ventilation activation mode by pressing the P a...

Page 14: ...re now erased 1 2 Flash x 2 BEEP DN DN UP UP P P S S 1 1 2 2 3 3 or Activate the opener only when door is in full view free of obstruction and properly adjusted No one should enter or leave the garage...

Page 15: ...the S button on the garage door opener 1 Connect the ethernet cable to the Liftmaster Internet Gateway and the router 2 Connect power to the Liftmater Internet Gateway 3 Create an online account on t...

Page 16: ...dby mode will need to be activated eg for using an external receiver To Activate NORMAL STANDBY mode Turn the mains power OFF Press and Hold both UP and DN buttons Turn ON mains power while both butto...

Page 17: ...ding call for professional garage door service Check to be sure that the door opens and closes fully Set the limits and or force if necessary SPECIAL NOTE Liftmaster strongly recommends that obstructi...

Page 18: ...side and remove the old battery Be sure to observe the polarity of the battery Assemble the transmitter again following the steps in reverse REPLACE BATTERIES IN REMOTES To prevent SERIOUS INJURY OR D...

Page 19: ...ener lights flash 10 times Check the obstruction detection beams if you have installed this accessory If the red light on the beam is flashing the alignment is incorrect The red light on the beams may...

Page 20: ...ure nothing is hanging or mounted on the door that would interrupt the sensors path while closing No RPM pulses have been detected Check the door manually for balance binding or obstructions Internall...

Reviews: