background image

4

Position the Header Bracket

The header bracket must be rigidly fastened to a structural
support of the garage. Reinforce the wall or ceiling with a 40 mm
(1-1/2") board if necessary. Failure to comply may result in
improper operation of safety reverse system.

You can attach the header bracket either to the header wall (1) or to
the ceiling (3). Follow the instructions which will work best for your
particular requirements. 

With the door closed, mark the vertical centerline (2) of the garage
door. Extend line onto header wall above the door.

Open door to highest point of travel. Draw an intersecting horizontal
line (4) on header wall 5 cm (2") above high point to provide travel
clearance for top edge of door.

12

Install the Header Bracket

NOTE: Refer to vertical center and horizontal lines created in step
12 for proper placement of header bracket.

A. Wall Mount:

Center the header bracket (1) on the vertical center

line (2) with the bottom edge of the header bracket on the
horizontal line (4) (with the arrow pointing toward the ceiling). Mark
all of the header bracket holes (5). Drill 4,5 mm (3/16") pilot holes
and fasten the header bracket with wood screws (3).

B. Ceiling Mount:

Extend vertical center line (2) onto the ceiling.

Center the header bracket (1) on the vertical mark no more than
150  mm (6") from the wall. Make sure the arrow is pointing toward
the opener. Mark all of the header bracket holes (5). Drill 4,5 mm
(3/16") pilot holes and fasten the header bracket with wood screws
(3). For concrete ceiling mount, use concrete anchors (6) provided.

13

INSTALLATION SECTION

Wear protective goggles when working overhead to protect your
eyes from injury.

Disengage all existing garage door locks to avoid damage to the
garage door.

To avoid serious personal injury from entanglement, remove all
ropes connected to the garage door before installing the opener.

Installation of this product shall comply with ZH1/494, VDE 0700
Part 238, and VDE 0700 Part 1.

It is recommended that the opener be installed 2,1m (7 feet) or more
above the floor where space permits.

3

1

2

4

2

50mm

(2")

3

1

4

B

A

3

6

150mm

  (6")

1

2

3

5

5

5

5

5

5

Attach Rail to Header Bracket

Position opener on garage floor below the header bracket. Use
packing material to protect the cover. Raise rail until holes in the
header sleeve and holes in the header bracket align. Join with clevis
pin (1). Insert ring fastener (2) to secure.

NOTE:

To enable the rail to clear sectional door springs, it may be

necessary to lift opener onto a temporary support. The opener must
either be secured to a support or held firmly in place by another
person.

14

1

2

2

1

1

2

114A3356

Summary of Contents for LM60K-MB

Page 1: ...Instructions Garage Door Operator Model LM60K MB LM60R MB 114A3356...

Page 2: ...doors must be repaired Garage doors door springs cables pulleys brackets and their hardware are under extreme tension and can cause serious personal injury Do not attempt to loose move or adjust them...

Page 3: ...crew 19 Stop Bolt 20 Carriage Bolt 21 Spring 22 Flat Washer Hardware Provided 3 4 Assemble the Rail Grease inside edges of rail sections using grease 1 Place rail pieces 2 on flat surface for assembly...

Page 4: ...3 3 1 2 3 4 5 7 5 4 6 1 3 2 1 3 2 Fasten Rail to Opener and Install Chain Belt Remove four washered bolts 1 from top of opener Place rail 2 on opener flush with stop 3 on top of opener Wrap chain bel...

Page 5: ...nto the ceiling Center the header bracket 1 on the vertical mark no more than 150 mm 6 from the wall Make sure the arrow is pointing toward the opener Mark all of the header bracket holes 5 Drill 4 5...

Page 6: ...a sturdy metal bracket not supplied 4 to a structural support before installing the opener For concrete ceiling mount Figure C use concrete anchors 5 provided On each side of opener measure the dista...

Page 7: ...6 4 5 7 3 Fasten Door Bracket If you have a canopy garage door a door arm conversion kit is required Follow the installation instructions included with the replacement door arm Exercise care in removi...

Page 8: ...off whenever the LEARN button on the control panel is activated 4 2 3 1 WHT 2 RED 1 5 6 6mm 1 2 4 WHT RED 1 4 LOCK LIGHT 3 3 2 3 Program your Opener Remote Activate the opener only when door is in fu...

Page 9: ...2 minutes Press again to turn it off sooner Lock feature Designed to prevent operation of the door from hand held remote controls However the door will open and close from the Door Control the Outsid...

Page 10: ...he door will not move up more than 500mm 27 2 4 2 2x 3 1 Install the Protector System See accessories The force as measured on the closing edge of the door should not exceed 400 N 40kg If the closing...

Page 11: ...1A2828 12B374 178B34 178B35 178B69 41B4616 4A1008 1 2 109A46 1 83A11 41A5643 3 12VDC Pb Cd Hg 12B380 12C778 41A5800 12C855 183D177 183D178 41A5887 31D536 31D533 41A5843 41A5801 210C42 12C777 144C77 14...

Page 12: ...11 Replacement Parts 31 32 41A589 1 41A5797 41A5734C 111A79 41D577 108C83 41A5908 158A49 114A3356...

Page 13: ...pener strains Door may be unbalanced or springs are broken Close door and use manual release rope and handle to disconnect trolley Open and close door manually A properly balanced door will stay in an...

Page 14: ...o pull the door opener or closed When the Opener is Activated by Remote Control or Lighted Door Control Button 1 If open the door will close If closed the door will open 2 If closing the door will sto...

Page 15: ...repaired or replaced unit or replacement batteries A product under warranty which is determined to be defective in materials and or workmanship will be repaired or replaced at Liftmaster s option at n...

Page 16: ...114A3356 2006 All rights reserved...

Reviews: