GB-5
Separate table for setting the operating modes
1. impulse opens, the next
one stops, the next one
closes, the next one opens
Impulse during closing opens
Impulse during the rest
closes the gate immediately
Standard
Standard & pedestrian function
1. impulse opens, the next
one closes, the next one
opens
1. impulse opens for pedestrians,
gate is moved open for 10 seconds
(fixed)
Impulse during the rest closes
the gate immediately
Channel separation
1. impulse opens, the next one
stops, the next one opens, the
next one stops etc.
No reaction if gate is closed
Impulse during closing stops
the gate, the next one opens
Car park
1. impulse opens the gate
completely, further impulses are
ignored
1 impulse opens for pedestrians
Impulse during the rest restarts
the rest time
No reaction during opening
Impulse during closing opens
the gate
No self-hold (hold to run)
Permanent signal required for
opening, letting go stops
Permanent signal required for
closing, letting go stops
Radio disabled, safety
equipment disabled, limit
switches are active
Radio disabled, safety equipment
disabled, limit switches are active
DIP1
ON
OFF
ON
ON
OFF
DIP2
ON
ON
ON
OFF
OFF
DIP3
OFF
OFF
ON
OFF
OFF
Impulse transmitter/channel 1
Impulse transmitter/channel 2
Impulse during opening stops the
gate, the next one closes
Impulse during closing stops the
gate, the next one closes, the next
one stops, the next one closes etc.
Impulse during the rest closes the
gate immediately
Impulse during closing fully opens
the gate immediately
Note:
If important safety equipment ( photocell/contact strip) is damaged, constantly active (switching) or if programmed equipment is not
connected, the control board operates without self-hold (hold to run). See description. For any corrections, check the status LEDs or see
functional description and “Frequently asked questions”.
709439
1. impulse opens for pedestrians,
gate is moved open for 10 seconds
(fixed), the next one closes, the
next one re-opens for pedestrians