32
DETERMINE AND SET WIRING TYPE (CONTINUED)
Programming
WIRING TYPE
DEVICE
ACTION
STATE
RESPONSE
TS
This mode will
attempt to close
the door from any
position
except when fully
closed, or when
a safety input is
present.
The stop button
will not disable the
Timer-To-Close
at any
position. To disable
the Timer-To-Close
in this mode,
installation of
a defeat switch
is required (see
wiring
diagram).
Momentary contact
to open, close, and
stop with open
override and
Timer-To-Close.
Every device that
causes
door to open,
including a
reversing device,
activates the
Timer-To-Close.
Auxiliary controls
can be connected
to open
input to activate the
Timer-To-Close. If
the timer has been
activated, the open
button and radio
control can recycle
the
timer. The Timer-
To-Close will
function from the
programmable
mid stop with
this wiring type.
Compatible
with 3-Button
Station, 1-Button
Station and 1 and
3-Button
Remote Control.
LiftMaster
Monitored
Entrapment
Protection (LMEP)
Device required.
3-Button
Control Station
OPEN button is pressed
momentarily
Operator at OPEN limit
No change in state
Operator at CLOSE limit
Door opens to closest OPEN limit or Mid-Stop
Door opening
No change in state
Door closing
Door will auto reverse to OPEN limit
Door at Open Mid-Stop
Door opens to the OPEN limit
Door stopped during open or close cycle
Door opens to the OPEN limit
CLOSE button is
pressed
momentarily
Operator at OPEN limit
Door closes to the CLOSE limit
Operator at CLOSE limit
No change in state
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
Door closes to the CLOSE limit
Door stopped during open or close cycle
Door closes to the CLOSE limit
STOP button is pressed
momentarily
Operator at OPEN limit
No change in state
Operator at CLOSE limit
No change in state
Door opening
Door stops
Door closing
Door stops
Door at Open Mid-Stop
No change in state
Door stopped during open or close cycle
Door stops
OPEN button is held
(constant pressure)
Operator at OPEN limit
No change in state
Operator at CLOSE limit
Door opens to closest OPEN limit or Mid-Stop
Door opening
No change in state
Door closing
Door will auto reverse to OPEN limit
Door at Open Mid-Stop
Door opens to the OPEN limit
Door stopped during open or close cycle
Door opens to the OPEN limit
CLOSE button is held
(constant pressure)
Operator at OPEN limit
Door closes to the CLOSE limit
Operator at CLOSE limit
No change in state
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
Door closes to the CLOSE limit
Door stopped during open or close cycle
Door closes to the CLOSE limit
3-Button
Remote Control
Programmed as
OPEN/CLOSE/STOP
OPEN button is pressed
momentarily
Operator at OPEN limit
No change in state
Operator at CLOSE limit
Door opens to closest OPEN limit or Mid-Stop
Door opening
No change in state
Door closing
Door will auto reverse to OPEN limit
Door at Open Mid-Stop
Door opens to the OPEN limit
Door stopped during open or close cycle
Door opens to the OPEN limit
CLOSE button is
pressed
momentarily
Operator at OPEN limit
Door closes to the CLOSE limit
Operator at CLOSE limit
No change in state
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
Door closes to the CLOSE limit
Door stopped during open or close cycle
Door closes to the CLOSE limit
STOP button is pressed
momentarily
Operator at OPEN limit
No change in state
Operator at CLOSE limit
No change in state
Door opening
Door stops
Door closing
Door stops
Door at Open Mid-Stop
No change in state
Door stopped during open or close cycle
Door stops
Single Button
Remote Control
Button is pressed
Operator at OPEN limit
No change in state
Operator at CLOSE limit
Door opens to closest OPEN limit or Mid-Stop
Door opening
No change in state
Door closing
Door will auto reverse to OPEN limit
Door at Open Mid-Stop
No change in state
Door stopped during open or close cycle
Door opens to the OPEN limit
Single Button
Control Station
(Wired)
Button is pressed:
Operator at OPEN limit
No change in state
Operator at CLOSE limit
Door opens to closest OPEN limit or Mid-Stop
Door opening
No change in state
Door closing
Door will auto reverse to OPEN limit
Door at Open Mid-Stop
No change in state
Door stopped during the open cycle
Door opens to closest OPEN limit or Mid-Stop
Door stopped during the close cycle
Door opens to closest OPEN limit or Mid-Stop
myQ
Door image is pressed:
Operator at OPEN limit
Door closes to the CLOSE limit
Operator at CLOSE limit
Door opens to closest OPEN limit or Mid-Stop
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
Door closes to the CLOSE limit
Door stopped during open or close cycle
Door closes to the CLOSE limit