30
DETERMINE AND SET WIRING TYPE (CONTINUED)
Programming
WIRING TYPE
DEVICE
ACTION
STATE
RESPONSE
FSTS
Momentary button
contact for open,
close and stop
programming. User
set mid stop. User
set Timer-To-
Close. The single
button station
opens the door to
the full open limit
bypassing the mid
stop and activates
the Timer-To-
Close, putting the
operator in TS
mode until the door
reaches the down
limit, or is stopped
in travel. At which
time the operator
enters the B2
mode. Compatible
with 3-Button
Station, 1-Button
Station, 1 and
3-Button Remote
Control. A 1-Button
remote control in
FSTS mode will
open only with the
Timer-To-Close,
bypassing a
programmed mid
stop. The Timer
To-Close will reset
and reverse when
closing.
LiftMaster
Monitored
Entrapment
Protection (LMEP)
Device required.
3-Button
Control Station
OPEN button is pressed
momentarily
Operator at OPEN limit
No change in state
Operator at CLOSE limit
Door opens to closest OPEN limit or Mid-Stop
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
Door opens to the OPEN limit
Door stopped during open or close cycle
Door opens to closest OPEN limit or Mid-Stop
CLOSE button is
pressed
momentarily
Operator at OPEN limit
Door closes to CLOSE limit
Operator at CLOSE limit
No change in state
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
Door closes to the CLOSE limit
Door stopped during open or close cycle
Door closes to the CLOSE limit
STOP button is pressed
momentarily
Operator at OPEN limit
No change in state
Operator at CLOSE limit
No change in state
Door opening
Door stops
Door closing
Door stops
Door at Open Mid-Stop
No change in state
Door stopped during open or close cycle
No change in state
OPEN button is held
(constant pressure)
Operator at OPEN limit
No change in state
Operator at CLOSE limit
Door opens to closest OPEN limit or Mid-Stop
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
Door opens to the OPEN limit
Door stopped during open or close cycle
Door opens to closest OPEN limit or Mid-Stop
CLOSE button is held
(constant pressure)
Operator at OPEN limit
Door closes to the CLOSE limit
Operator at CLOSE limit
No change in state
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
Door closes to the CLOSE limit
Door stopped during open or close cycle
Door closes to the CLOSE limit
3-Button
Remote Control
Programmed as
OPEN/CLOSE/STOP
OPEN button is pressed
momentarily
Operator at OPEN limit
No change in state
Operator at CLOSE limit
Door opens to closest OPEN limit or Mid-Stop
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
Door opens to the OPEN limit
Door stopped during open or close cycle
Door opens to closest OPEN limit or Mid-Stop
CLOSE button is
pressed
momentarily
Operator at OPEN limit
Door closes to the CLOSE limit
Operator at CLOSE limit
No change in state
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
Door closes to the CLOSE limit
Door stopped during open or close cycle
Door closes to the CLOSE limit
STOP button is pressed
momentarily
Operator at OPEN limit
No change in state
Operator at CLOSE limit
No change in state
Door opening
Door stops
Door closing
Door stops
Door at Open Mid-Stop
No change in state
Door stopped during open or close cycle
No change in state
Single Button
Remote Control
Button is pressed
Operator at OPEN limit
No change in state
Operator at CLOSE limit
Door opens to the OPEN limit
Door opening
No change in state
Door closing
Door will auto reverse to OPEN limit
Door at Open Mid-Stop
Door opens to closest OPEN limit
Door stopped during open or close cycle
Door opens to closest OPEN limit or Mid-Stop
Single Button
Control Station
(Wired)
Button is pressed:
Operator at OPEN limit
No change in state
Operator at CLOSE limit
Door opens to the OPEN limit
Door opening
No change in state
Door closing
Door will auto reverse to OPEN limit
Door at Open Mid-Stop
Door opens to the OPEN limit
Door stopped during the open cycle
Door opens to the OPEN limit
Door stopped during the close cycle
Door opens to the OPEN limit
myQ
Door image is pressed:
Operator at OPEN limit
Door closes to the CLOSE limit
Operator at CLOSE limit
Door opens to closest OPEN limit or Mid-Stop
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
Door closes to the CLOSE limit
Door stopped during open or close cycle
Door closes to the CLOSE limit