The gate opener doesn’t respond at all; no LED is
on. 

Possibly power failure. 

1. Check conductor and zero conductor. 
2. Check house fusing. 
Check whether the radio module is
seated correctly.

Immediately after the gate has started moving, it
stops and reverses. 

Obstacle in area of gate. 
Gate rough running (consult dealer)

Check gate area for objects 
check photocells
reprogram travel distance

Gate can only be opened

photocell blocks

Function and connection must be
checked

“Timer to close” doesn’t work.

Only works if the 2-cable photocell 771E(ML) 
or 772E(ML) installed. 

The control board does not work any more using
the transmitter, only with the switch and even then
only as long as a button is pressed and kept
pressed. 

Photocell, a safety edge or the emergency
stop disables the control board
Only one photocell was connected for OPEN

At least 1 pair of photocells active in
OPEN or CLOSED must be connected

The gate opener doesn’t respond at all, although
the controller has been connected (LEDs are on). 

1. Remote control not programmed. 
2. LEDs indicate a fault. 
3. Photocell connected incorrectly. 
4. Motor terminal possibly not connected 

properly. 

1. Programming remote control. 
2. Find and rectify fault(s) (see description of 

diagnostic LEDs). 

3. Check photocell connection / programming. 
4. Check terminals and connections. 

The remote control’s range is too short. 

The installation of an external aerial is recommended as the controller with the short cable
aerial is located either behind the post or near ground level in most cases. The optimum
location of the aerial is as high as possible in all cases. An appropriate aerial with installation
kit can be obtained from Chamberlain as an accessory. 

The gate must follow a slope. 

Not recommended! Change gate! The gate can move in an uncontrolled (dangerous) manner if
the gate opener has been released. A stronger force is needed in the upwards direction of the
slope and then, in the opposite direction, the gate opener’s force is too strong. 

FAQs

Pressing P1, P2 and P3 does not show any reaction

Jumper “RADIO” must be removed
Check whether the radio module is
seated correctly.

Travel distance can’t be programmed.

1. Jumper setting not correct
2. see Diagnostic LED
3. interferences in wiring of photocells, switch  

or safety edge  

4. Gate moves for 1 second only and stops 

without reversal during programming

5. Magnetic limit switch

1: follow the instructio of “Initial Operation” 

closely

3: remove for checking, then re-program 

travel distance

4: check RPM sensor/Encoder on control 

board 

5: install magnetic limit switch properly

The operator sometimes movess slowly 

Powerfailure

Common procedure. After powerfailure the
operator performs a selftest. Depending on
the operator model this can take a few
seconds or a complete cycle. Do not interrupt
this test via remote control or switch,
otherwise the limits may change. If this is the
case reprogram travel distance using P1.

Control board does not work

travel distance not programmed

Program travel distance. See initial
operation / diagnosis LED

Control board does not work with transmitter

1. transmitter not programmed
2. photocells block
3. Jumper “RADIO”

1.Program transmitter
2.Check photocells, check diagnostic LEDs
3. Jumper “RADIO” must be plugged.

Gate doesn’t open completely

Gate heavy / rough running

re-program travel distance
consult dealer/specialist

Limit switches OPEN and CLOSED nicht correctly
indicated

incorrect programming

During programming the limit switch  OPEN
must be reached using P1, then limit switch
CLOSED. Switching motor cables is not
required.

Gate opens instead of closing automatically
(Timer to close activated)

incorrect programming

repeat programming as described in these
instructions

Summary of Contents for CB202

Page 1: ...Nobel Strasse 4 66793 Saarwellingen Germany www liftmaster eu info liftmaster eu Anleitungen CB202 Instructions CB202 Instructions CB202 Návody CB202 Instrucciones CB202 Instruktioner CB202 Útmutatók CB202 Upute CB202 Istruzioni CB202 Instruktie CB202 Obrázky CB202 Instrukcja CB202 en fr de es hr sv cs hu it nl sk pl ...

Page 2: ... TERMINALS 5 DESCRIPTION OF LEDS 5 DESCRIPTION OF PUSH BUTTONS P1 P2 P3 5 BACKUP BATTERY 6 FLASHING LAMP 6 KEYSWITCH 6 STOP SWITCH 6 SAFETY EDGE 6 CONTACT EDGE 6 ANTENNA 6 PHOTOCELLS 7 RADIO AND RADIO PROGRAMMING 7 LOOP DETECTOR 8 JUMPER SETTINGS 8 INITIAL OPERATION BASIC SETTING 9 11 TIMER TO CLOSE AUTO CLOSE 11 FORCE TORQUE OF MOTOR 11 BATTERY DISPOSAL 11 DIAGNOSIS LED 12 FAQ S 13 ...

Page 3: ...y from children Do not allow children to play with pushbuttons or remote controls A gate can cause serious injuries as it closes After the installation a final test of the full function of the system and the full function of the safety devices must be done The full protection against potential squeeze or entrapment must work direct when the drive arms are installed This drive cannot be used with a...

Page 4: ...sary assemble the following optional connections photocells safety edge flashing light external antenna key switch or other external control devices TYPICAL CONFIGURATION OF A UNIT 1 Drive with control board The drive is located on a height adjustable mounting plate 2 Photocell min 150 max200 mm optional First photocell Detects low objects 3 Photocell max 700 mm optional Second photocell Detects v...

Page 5: ... controller Even if a terminal strip is not in use it must be pushed back The wiring is done as described in the wiring diagram Plugs available on the motor and the transformer These plugs must be connected to the controller plugged in The cable of the connectors are not routed from below but from the back of the controller see picture 1 230 Volt transformer feeder TRANSF IN and INPUT 24 VAC 2 Lim...

Page 6: ...e Remote control max 180 x Rolling Code feasible frequencies 433 MHz 868 MHz The motor control unit is a highly modern electronic unit controlled by a microprocessor It has all wiring facilities and functions required for safe operation The electronics provides an ideal and matching closing force When installed and adjusted correctly the gate can be stopped manually During operation the gate can b...

Page 7: ... red cable 24 V 150 mA flashing light accessory Key symbol keyswitch other control devices COM negative pole PHOTO2 photocells 2 accessory PHOTO1 photocells 1 accessory COM negative pole STOP stop switch or 8 2 kOhms safety edge with 8 2 KOhms accy RPM ENCODER socket for rpm sensor LIMIT SWITCH socket for limit switch RADIO MODULE SCKT socket for radio module ANT terminal for antenna 2 A 2x slow b...

Page 8: ...atteries are subject to deterioration and lose capacity Replace storage batteries after approx 2 3 years CM475 is not for outside use and requires a suitable enclosure SAFETY EDGE OPTIONAL MODEL 600046 600053 600077 600060 Jumper must be free A safety edge working according to the 8 2 kilo ohm principle can be connected to the control board Terminals Stop 8 2 kOhm i e a 8 2 kilo ohm test resistor ...

Page 9: ... is closing Jumper PHO 2 MODE plugged active when gate is closing and opening RADIO AND RADIO PROGRAMMING Insert radio module on designated pins if not pre installed PROGRAM DELETE REMOTE CONTROLS The receiver has two channels CH1 and CH2 The respective LEDs CH1 and CH2 are assigned to these two channels Receiving a signal from a programmed remote control button CH1 fully opens the gate Receiving ...

Page 10: ... the second photocell is active in closing or in closing opening FREE active in closing PLUGGED active in closing and opening FIXED WIRE JUMPER OBSTACLE Factory equipped with fixed wire jumper Cutting through increases the operating power at the control CAUTION If the jumper is severed the door system must be secured with additional safety devices safety edge etc Werkseitig mit fester Drahtbrücke ...

Page 11: ...further settings are made 5 Close the gate with the button P1 till it is turned off at the limit switch CLOSED Do not release beforehand Control The LED CLOSE LIM yellow limit switch CLOSED should now light up and the door can be closed as desired Basic setting is completed 2 2 2 INITIAL OPERATION BASIC SETTING Proceed step by step When in doubt start again at the beginning Take sufficient time to...

Page 12: ...glows 2 Press the button P1 until the door starts to open LED LEARN glows The automatic programme starts slow speed 3 The drive moves the gate to the limit switch OPEN stops briefly and then moves back to the limit switch CLOSED 4 After reaching the limit switch CLOSED the LED LEARN goes out The programming of the distance and the force required is completed Proceed with Radio an Radio Programming...

Page 13: ... points Batteries and rechargeable batteries are marked with a crossed waste container as well as with the chemical symbol which describes their toxic element Cd for cadmium Hg for mercury and Pb for lead en 11 12VDC Pb Cd Hg COMPLETION OF INSTALLATION PROGRAMMING Once the travel distances are programmed the remote controls can be programmed as well Refer to Radio and Radio Programming 1 You can n...

Page 14: ...y or rough running B Gate blocked or rough running at a certain position C Gate not balanced D Faulty mechanical installation All consult gate dealer specialist 6x blinking Photocells 1 block installation A Obstacle interrupts beam A remove obstacle B poor alignment of the lenses B check alignment C power supply for photocells not sufficient C check terminals and wire diameter 7x blinking Photocel...

Page 15: ...e The gate can move in an uncontrolled dangerous manner if the gate opener has been released A stronger force is needed in the upwards direction of the slope and then in the opposite direction the gate opener s force is too strong FAQs Pressing P1 P2 and P3 does not show any reaction Jumper RADIO must be removed Check whether the radio module is seated correctly Travel distance can t be programmed...