en-5
DESCRIPTION OF LEDS (LIGHT EMITTING DIODE)
DESCRIPTION COLOUR
STATUS
STOP / 8.2 kOhms
green
Stop Switch
ON: Stop Active
OFF: OK
(Requires wire bridge if no
switch is connected)
EDGE
green
Safety Edge 8.2KOhm
ON: Activated
OFF: OK
(Requires 8.2KOhm resistor if not used)
“Key symbol” red
Key-switch
ON: Activated
OFF: OK
PHO 1
red
Photocell 1 (close)
ON: OK, photocell connected
OFF: No photocell connected
PHO 2
red
Photocell 2 (adjustable)
ON: OK, photocell connected
OFF: No photocell connected
OPEN LIM
yellow
limit switch GATE OPEN
CLOSE LIM
yellow
limit switch GATE CLOSED
LEARN
yellow
Programming indicator
ON: (flashing) programming is active
OFF: off
DGN
red
Diagnostic, also refer to page 12
CH1
red
Remote control programming for
complete opening
ON: New remote can be
programmed
OFF: off
CH2
red
Remote control programming for
partial opening (Refer to CH1)
DESCRIPTION OF TERMINALS
Description
Function
120 -230 VAC
50 - 60 Hz
POWER SUPPLY
connector
TRANSF IN
230 V to transformer
INPUT 24 V
24 V from transformer
30 VDC
output 30 VDC
or terminal for battery kit
CM475 + 041ADBL-0115
Motor
blue cable
Motor
red cable
24 V / 150 mA
flashing light (accessory)
Key symbol
keyswitch, other control devices
COM
negative pole
PHOTO2
photocells 2 (accessory)
PHOTO1
photocells 1 (accessory
COM
negative pole
STOP
stop switch or
8.2 kOhms
safety edge with 8.2 KOhms (accy)
RPM / ENCODER
socket for rpm-sensor
LIMIT SWITCH
socket for limit switch
RADIO MODULE SCKT
socket for radio module
ANT
terminal for antenna
2 A
2x slow-blow fuse included 250V/2A
DESCRIPTION OF PUSH BUTTONS P1, P2, & P3
Button
Function
P1+P2+P3
Limit setting:
Push P1+P2+P3 simultaneously. The LED LEARN starts to flash as long as feature is activated.
P1
Button P1
operates Motor
. Deactivate: Wait for 20 seconds or disconnect logic board from power.
P1
Force / travel distance - setting “BASIC”
; from position CLOSE LIM
P1 + P2
Force / travel distance - setting “ADVANCED”
; from position CLOSE LIM;
with option Soft-Stop setting
P2 ; P3
Timer to close.
Factory setting: off. When the photocell beam is interrupted, the gate closes immediately without delay.
Activate: Press P2 + P3 until LED “lern” flashes. 1x = off, 2x = on
P3
Software-reset
to factory defaults. Push & hold for 10 seconds. Does not reset memory (see section “radio”).
Radio P1
Programming Remote for Channel 1
Command for OPEN completely
Radio P2
Programming Remote for Channel 2
Command for OPEN partially