4
1
Diagnostic Chart
Your garage door opener is programmed with self-diagnostic capabilities. The UP and DOWN arrows on the garage door opener flash the diagnostic codes.
DIAGNOSTIC CODE SYMPTOM
SOLUTION
Flashes
Flashes
1
1
The
garage
door
opener
will
not
close.
Safety
reversing
sensors
are
not
installed,
connected,
or
wires
may
be
cut.
Inspect
sensor
wires
for
a
disconnected
or
cut
wire.
1
2
The
garage
door
opener
will
not
close
.
.
There
is
a
short
or
reversed
wire
for
the
safety
reversing
sensors.
Inspect
safety
sensor
wire
at
all
staple
and
connection
points,
replace
wire or correct as needed.
1
3
The door control will not function.
The wires for the door control are shorted or the door control is faulty. Inspect door control wires at all staple and connection points,
replace wire or correct as needed.
1
4
The
garage
door
opener
will
not
close.
Safety
reversing
sensors
are
misaligned
or
were
momentarily
obstructed.
Realign
both
sensors
until
both
LEDs
are
glowing
steady.
Make
sure nothing is hanging or mounted on the door that would interrupt the sensor’s path while closing.
1
5
Door moves 6-8" (15-20 cm) stops or reverses.
Manually open and close the door. Check for binding or obstructions, such as a broken spring or door lock, correct as needed. Check
wiring connections at travel module and at the logic board. Replace travel module if necessary.
No movement, only a single click.
Manually open and close the door. Check for binding or obstructions, such as a broken spring or door lock, correct as needed. Replace
logic board if necessary.
Opener hums for 1-2 seconds no movement.
Manually open and close the door. Check for binding or obstructions, such as a broken spring or door lock, correct as needed. Replace
motor if necessary.
1
6
Door coasts after it has come to a complete stop.
Program travel to coasting position or have door balanced by a trained door systems technician.
2
1-5
No movement, or sound.
Replace logic board.
3
2
Unable to set the travel or retain position.
Check travel module for proper assembly, replace if necessary.
3
3
The battery status LED is constantly flashing green.
Battery backup charging circuit error, replace the logic board.
4
1-4
Door is moving, stops or reverses. Opener beeps and lights
flash.
Manually
open
and
close
the
door.
Check
for
binding
or
obstructions,
such
as
a
broken
spring
or
door
lock,
correct
as
needed.
If
the
door
is
binding
or
sticking
contact
a
trained
door
systems
technician.
If
door
is
not
binding
or
sticking
attempt
to
reprogram
travel,
see
Program
the
Travel
page
3
2
.
4
5
Opener runs approximately 6-8" (15-20 cm), stops and
reverses.
Communication error to travel module. Check travel module connections, replace travel module if necessary.
4
6
The
garage
door
opener
will
not
close
.
Safety
reversing
sensors
are
misaligned
or
were
momentarily
obstructed.
Realign
both
sensors
to
ensure
both
LEDs
are
steady
and
not
flickering. Make sure nothing is hanging or mounted on the door that would interrupt the sensor’s path while closing.
Troubleshooting