background image

 

  

 
 

 

 

I-PR3I-01.doc 

 

 

Issue 03  

18/07/2019 

 

 

 
 
 
 

                                             IOM 

 

PROTECTA LED (IND)

 

 

0.0 

Specification

 

 

Type Of Protection   

N/A 

Standards 

EN 60598-1, EN 60598-2-22 

Area Classification 

Industrial, (Non- Hazardous)  

Ambient 

 

 -25°C to +45°C

 

Ingress Protection 

IP66/67 to EN 60529   

CE Mark 
 

The  CE  marking  of  this  product  applies  to  "The  Electrical  Equipment  (Safety)  Regulations 
2006",  "The  Electromagnetic  Compatibility  Regulations  2004",  the  “Waste  Electrical  and 
Electronic  Equipment  Regulations  2006”.   [This  legislation  is the  equivalent in  UK law of EU 
directives 2014/35/EU, 2014/30/EU, 2012/19/EU respectively]. 
 

M Poutney    Technical Manager 

 

Luminaire is supplied with Battery plug/Socket disconnected, just prior to switching 
power on, connect battery plug and socket. 

 

1.0  Introduction - Protecta Safe Area LED Luminaire 

The  Protecta  Safe  Area  LED Luminaires  are  surface  mounted  or  suspended,  utilising  the two tapped holes on 
base of body, with the facility of an integral battery back-up for emergency use.  Normal operation is mains supply 
LEDS  full  on,  switching  to  reduced  LED  power  on  battery  back-up,  local  switching  of  the  mains  LEDS,  the 
emergency  output  only  being  energised  on  mains  failure.    Emergency  duration:  to  BS  EN  60598  2.22,  as  per 
order.    They  are  mainly  used  in  harsh  environments  and  are  constructed  using  a  corrosion  resistant  glass 
reinforced polyester body attached to an injection moulded polycarbonate diffuser by hinges and a special clamp.  
The control gear and LED strips are mounted on a removable tray which for maintenance has hanging straps. 
 

2.0   Storage

 

Luminaires  and  control  gear  boxes  are  to  be  stored  in  cool  dry  conditions  preventing  ingress  of  moisture  and 
condensation.  Any specific instructions concerning emergency Luminaires must be complied with. 
Battery  packs  in  storage  should  be  cycled  charged/discharged/charged  every  9  months,  as  per  instructions 
below.  

Always disconnect battery plug and socket for storage

Any specific instructions concerning emergency luminaires must be complied with. 
(Warning: Battery packs not cycled and stored for a year may not be recoverable) 
 

3.0    Installation and Safety

 

3.1   General

 

There  are  no  health  hazards  associated  with  this  product  whilst  in  normal  use.    However,  care  should  be 
exercised during the following operations.  
In the UK the requirements of the 

'Health and Safety at Work Act'

 must be met. 

Handling  and  electrical  work  associated  with  this  product  to  be  in  accordance  with  the 

'Manual  Handling 

Operations Regulations' and 'Electricity at Work Regulations, 1989'

.  Your attention is drawn to the paragraphs (i) 

'Electrical  Supplies',  (ii)  'Electrical  Fault  Finding  and  Replacement'  and  (iii)  'Inspection  and  Maintenance'.    The 
luminaires are Class 1 and should be effectively earthed. 
The  information  in  this  leaflet  is  correct  at  the  time  of  publication.    The  company  reserves  the  right  to  make 
specification changes as required. 
 

3.2   Tools

 

12mm, 5mm and 3mm flat blade screwdriver. Pozi number 2 screwdriver 
Suitable spanners for installing cable glands. Pliers, knife, wire strippers/cutters. 
 

3.3    Electrical Supplies and Control Gear

 

Luminaires fitted with electronic control gear are suitable for a rated supply from 120- 277Vac 50-60Hz, 
127-300V dc for standard fitting and 220-240V 50/60Hz for emergency. The safety limits are +10% of this.  The 
supply would normally be expected to lie /-6% of rated. The LED supply is regulated, therefore the light 
output over the range is substantially unchanged. 
 
Electronic gear has integrated power factor correction to >0.90. 

Summary of Contents for Protecta Series

Page 1: ... Protecta LED Luminaires Industrial Important Please read these instructions carefully before installing or maintaining this equipment Good electrical practices should be followed at all times and this data should be used as a guide only MODEL SIZE DIMENSION A DIMENSION B 02L 742 400 04L 742 400 07L 1352 700 ...

Page 2: ...e and condensation Any specific instructions concerning emergency Luminaires must be complied with Battery packs in storage should be cycled charged discharged charged every 9 months as per instructions below Always disconnect battery plug and socket for storage Any specific instructions concerning emergency luminaires must be complied with Warning Battery packs not cycled and stored for a year ma...

Page 3: ...and 6mm are available State which on order If work is to be done on any Luminaire which has already been connected to the electrical system it must be isolated from the system The diffuser cover is swung down and removed if convenient by swivelling back as far as possible and the reflector tray is then slid out after releasing the locking screws This gives access to the mains terminals Standard fi...

Page 4: ...5 Commissioning Energise the mains and check that LED s light when the supply is energised Emergency luminaires are supplied with the Battery plug Socket disconnected Just prior to switching power on connect battery plug and socket Emergency luminaires will require battery packs to be cycled to obtain the full duration capacity of the Ni Cd battery cells It is recommended that the unit is charged ...

Page 5: ...ge and replace if necessary 8 If it has been suspected that the Luminaire has suffered mechanical damage a stringent workshop check on all components should be made All components can be removed from the Luminaire for inspection 4 0 Electrical Fault Finding and Replacement The supply must be isolated before opening the Luminaire Any live fault finding must be done by a competent electrician and if...

Page 6: ...ry will remain on charge for an uninterrupted 24 hours At this time the module will conduct a commissioning test for the full duration The 24 hours recharge occurs also if a new battery is connected or the module exits the rest mode condition The following automatic commissioning duration test is only performed when a battery is replaced and fully charged after 24 hrs and the interval time is not ...

Page 7: ... test underway Slow flashing green 1 sec on 1 sec off Duration test underway Red LED on Load failure Open circuit Short circuit LED failure Slow flashing red 1 sec on 1 sec off Battery failure Battery failed the duration test or function test Battery is defect or deep discharged Incorrect battery voltage Fast flashing red 0 1 sec on 0 1 sec off Charging failure Incorrect charging current Green and...

Page 8: ...lektronischen Geräte Systeme 2011 65 EU RoHS II Directive On behalf of the Chalmit I declare that on the date the equipment accompanied by this declaration is placed on the market the equipment conforms to all technical and regulatory requirements of the above listed directives En tant que représentant du fabricant Chalmit je déclare qu à la date où les équipements accompagnant cette déclaration s...

Reviews: