PROTECTA LED (IND)
LED Indicator
- A bi-colour LED indicates the status of the module as follows:
LED Indication
Status
Comment
Permanent green
System OK
AC mode
Fast flashing green
(0,1 sec on – 0,1 sec off)
Function test underway
Slow flashing green
(1 sec on – 1 sec off)
Duration test underway
Red LED on
Load failure
Open circuit / Short circuit / LED failure
Slow flashing red
(1 sec on – 1 sec off)
Battery failure
Battery failed the duration test or function test /
Battery is defect or deep discharged/
Incorrect battery voltage
Fast flashing red
(0,1 sec on – 0,1 sec off)
Charging failure
Incorrect charging current
Green and red off
DC mode
Battery operation (emergency mode)