6.0 Operation
26
6.12.3 Diagnostic
The diagnostic area can be very helpful in locating a problem in the event of a machine malfunction.
Use the up and down arrow keys to toggle to the desired selection, and press ENTER. See the
following descriptions for an explanation of each.
6.12.3.1 Error Code
The Error Code function simply recalls the last five error messages that were displayed. This can be
very useful in cases when the malfunction cannot be reproduced in the presence of the service
technician.
6.12.3.2 Sensor Data
The Sensor Data function provides a list of computer inputs and outputs (proximity switches, etc.)
along with their status (0 for open, 1 for closed). This function allows a service technician to check
the status of a switch without removing any covers. Cuts and backgauge movements are allowed in
this screen so that the technician may observe the status of the inputs and outputs during machine
operation.
6.12.3.3 Clear Memory
The Clear Memory function resets the memory to a known state.
All cut positions will be erased
during this operation
.
6.12.3.4 Electric Clamp
This function turns the optional electric clamp pressure control on or off.
6.12.3.5 Clamp Adjust
This function allows for the adjustment of the electric clamp function.
6.12.4 Language
In the language screen, use the up and down arrow keys to toggle to the desired language, and press
ENTER. All messages will be displayed in the selected language.
5.000
in
DIAGNOSTIC
Error Code
Sensor Data
Clear Memory
Electric Clamp
Clamp Adjust
A) Maint
C) Send
B) Job
D) Exit