5.0 Installation & Setup
11
5.4.2 Removing the Table
1.
Make sure the knife and clamp are in the “up” position. If they are not, read the Power
Hookup section (page 16) to connect power to the machine. Turn on the power using the red
and yellow main power switch and press the CLEAR button. This will preset the backgauge
and send the knife and clamp up.
2. Turn off the machine and unplug the power cord.
3. Make sure the side tables and side table mounting brackets have been removed (see
previous section).
4. Remove the cut buttons from the bottom of the table.
5. Remove all rear covers that are on the rear of the table. Remove the backgauge motor
cover, the rear table support leg, the lower back panel, and the lower front cover of the
machine.
6. Unplug the cable to the encoder at the back of the machine (Figure 5).
Figure 5
7. Remove the motor junction box cover and disconnect the wires to the motor (Figure 6).
Remove the leadscrew cover and the nylon wire-ties that are attached to the bottom of the
table. The motor wires and encoder wires should now be free from the table.
8. If this machine is equipped with an Air Table
– unplug the three air hoses from the bottom of
the table
Encoder Plug
Rear Support
Leg