![CHAFFOTEAUX PIGMA Gal Evo Training Handbook Download Page 49](http://html1.mh-extra.com/html/chaffoteaux/pigma-gal-evo/pigma-gal-evo_training-handbook_2585755049.webp)
Pag. 49 de 73
Manuale Didattico – ACO
Training manual :PIGMA Gal Evo
5.6
EXTRACTOR (SUCTION CAP TYPE DESIGN)
Technical data :
-
25kW: Motor 35W
-
30kW: Motor 45W
-
35 kW Motor 60 W
5.7.1.POST-VENTILATION
Different cycles of post ventilation according to the cases
of figures:
during a setting to safety
5 01
:
40 seconds
during a setting to safety linked to water circulation
1 03
,
1 04
,
1 05
,
1 06
or
1 07
:
20 seconds
during a fault in water flow circulation
1 P1
,
1 P2
or
1 P3
: 10 seconds
►Post-ventilation after a heating request:
parameter
2 43
= 0
5 seconds ( at each burner firing stop)
parameter
2 43
= 1
3 minutes ( at each burner firing stop)
►Post-ventilation after a sanitary request:
parameter
2 54
= 0
T°Dép<75°C = No post-ventilation; start T°>75°C = 3 min
parameter
2 54
= 1
fix 3 min (at each burner flame out).
Connector CN 22
(brackets 11 and 12) of
electronic PCB
NC
NA
NC
NA
Connector CN 22
(brackets 11 and 12) of
electronic PCB
FAN OFF
Pressure
tap (-)
Pressure
tap(+)
FAN ON