Picture 12 – Model on base structure
3. Water connection
1. The operating pressure is indicated on the data
plate of the water heater (see water heater).
The connection of a water heater to copper
piping must be performed using a
dielectric
connection
. These dielectric connections are
available as an optional extra or as standard,
depending on the model purchased.
If you only have one dielectric connector, you must
ÀWLWWRWKHKRWZDWHURXWOHW
4. If the water systems have the following
features:
small pipes;
taps with ceramic plates / mixer taps;
a “ram stabilising” device or a domestic hot water
expansion vessel suited to the system must be
installed as close as possible to the taps.
We recommend that a shut-off valve
is installed upstream from the safety
assembly.
See pictures 6, 7, 8, 9, 10, and 12.
A : Hot water / B : Cold water / C : Safety assembly / D : Shut-off valve / E : Dielectric connection
THE WIRING DIAGRAM IS STUK
ONTO THE APPLIANCE: USE IT AS A
REFERENCE GUIDE.
4.2. The models with TM and TR designation
are three-phase versions (TRI):
ANY DIRECT CONNECTION TO THE
HEATING ELEMENT IS HAZARDOUS
ANS IS STRICTLY PROHIBITED.
4. Electrical connection
4.1. Important considerations
2.
!
DTU
Connection with materials synthesis
PER are prohibit: flood risk
To connect the tank on plastic pipe “PER” installa-
tion existent, intercalate on the out-let (hot water)
a copper pipe with minimum longer 50 cm to avoid
any damage.
2.2.d. STAB models on base structures
This appliance is
ÀWWHG
with a base structure
which is
À[HG
to the product while it is still at the
company. Position the appliance on a perfectly
ÁDW
and level surface.
installed upstream of the safety assembly.
3. When the input pressure of the network is
greater than 4.5 bar, a pressure reducer must be
depending on model
Picture 11 – Model on base structure
These three-phase devices are wired in 400 V TRI
by the manufacturer. They can be connected 230V
TRI or 230V single-phase (see wiring diagram on
the device).
4.3. The models with MT designation are
three-phase devices:
These devices are wired 230V single phase by the
manufacturer and can be connected to 230V TRI
or 400V TRI (See wiring diagram on the device)
The 500 liters floor standing model is wired
400V TRI by the manufacturer. The electrical
connection of the device is made exclusively
on the thermostat’s terminals or on the
device’s terminal board.
Picture 14 - A dielectric connector
Summary of Contents for 470 VERT
Page 3: ...FR 3 ...
Page 4: ...FR 4 ...
Page 5: ...FR 5 ...
Page 8: ...FR 8 ...
Page 9: ...FR 9 ...
Page 21: ...FR 21 ...
Page 22: ...NL 22 ...
Page 23: ...NL 23 ...
Page 24: ...NL 24 ...
Page 25: ...NL 25 1 97 ...
Page 36: ...36 NL 36 ...
Page 37: ...DE 37 ...
Page 53: ...DE 53 ...
Page 54: ...EN 54 ...
Page 55: ...EN 55 ...
Page 69: ...EN 69 ...
Page 70: ......
Page 71: ......
Page 72: ...72 ...
Page 73: ...EN 73 ...
Page 74: ...74 ...
Page 75: ...75 ...