O
Any state
Enters Shortcuts mode
Q
Any state
No effect
Push buttons actions in Normal mode
4.2.2 Shortcuts
The M1.1 amplifier settings are accessible through a set of menus as described in the next sections. However, to allow quick access
to the most frequently used configuration menu items, the M1.1 offers the concept of Shortcuts. Shortcuts are fully programmable
and the user may choose any configuration parameter as a Shortcut. There are up to 6 user programmable Shortcuts. To learn how
to program individual Shortcuts, please refer to the SHORTCUTS menu item in the next section. There is no shortcut defined within
the Factory default settings.
Shortcuts are accessed from Normal mode by pushing the OK [
R
], UP [
N
] or DOWN [
O
] buttons on the front face. Additional OK
[
R
] pushes toggle through the Shortcut list. The last Shortcut is always dedicated to entering the Menu mode (SETUP). On this last
Shortcut, an OK [
R
] push will return to Normal Mode while an UP [
N
] push will enter the Menu mode. The individual parameter
for a given Shortcut is modified using UP [
N
] or DOWN [
O
] buttons. The unit will revert to Normal mode if no action is taken for
about 10 seconds.
The following table shows the actions of the push buttons for the Shortcuts.
Front panel push buttons
Unit State
Unit Action
STANDBY [
S
] Short Push
Any state
Mutes/Unmutes unit
STANDBY [
S
] Long Push
Any state
Goes to STANDBY
UP [
N
]
Shortcuts (except last)
Last Shortcut (SETUP)
Modifies parameter up (when available)
No action
OK [
R
]
Shortcut (except last)
Last Shortcut (SETUP) or
after current Shortcut has
been modified
Skips to next Shortcut
Confirms the new selection and exits Shortcuts mode (Normal
mode)
DOWN [
O
]
Shortcuts (except last)
Last Shortcut (SETUP)
Modifies parameter down (when available)
Enters Menu mode
CANCEL [
Q
]
Shortcuts
Exits Shortcuts mode (Normal mode)
Push buttons actions for the Shortcuts