18
Do not locate the probe above or near the steam head or direct steam
emissions. The probe is 10ft cable. Ensure that the probe and
controller are located accordingly.
IMPORTANT NOTE: Do not strain, staple, pinch, otherwise damage the
probe cable.
Start the steam generator
After confirming that the pipes and circuits are installed correctly, you
could open the water valve and turn on the power switch. Press the
ON/OFF and the machine will start to work. After heating for minutes,
the machine starts to emit steam, and stops steaming until the room
reaches the set temperature.
Press the ON/OFF button again to turn off the machine. The controller
will display the current temperature in the shower room when it is
working. The temperature setting range of the controller is between
95-131℉.
Warnings;
·
The machine must be connected with the ground.
·
Do not install the machine and controller in wet place. It should be
installed in dry and ventilated place. Our company will not take
the responsibility if it is damaged by wet.
·
The double-sided adhesive on ST-135 the controller’s back can not
work for fixed function and glass glue should be used to fix.
Controller’s operation direction
1, temperature display window; the temperature is shown in shower room
when steam generator in work
2, heating indicator light; generator is heating for steam when lights on
3, heat lamp; shower room reaches setting temperature when light on, the